stud
bud
Sign up
Log in
Home
Library
Explore
SAT
More
Complex Hemodynamic Monitoring Flashcards | StudBud
Explore
/
Complex Hemodynamic Monitoring
Complex Hemodynamic Monitoring
31 terms
·
StudBud Administration
·
19 plays
Imported from external platform
Flashcards
31 cards
F
Practice quiz
P
Host live
L
Questions
31
Answers
1
balloon inflated in rigt ventricle w/air to read pulm art blood flow (monitorsO2)
Venous Oxygen Saturation Monitoring
Pulmonary Artery Flow-Directed Catheter
2
Volume of BLOOD in Liters pumped by <3 in 1 min
Stoke Volume (SV)
Cardiac Output (CO)
Stoke Volume Index (SVI)
Cardiac Index (CI)
3
Invasive BP monitoring in radial or ulnar artey (immbolize insertion site) Watch infection, bleeding, & loss of limb
Arterial BP
Zeroing
Arterial Pressure Based Cardiac Output (APCO)
Dynamic Response Test
4
Determines continous CO & CI. Assess pt ability to respond to fluids by increases SV (preload responsiveness)
Arterial Pressure Based Cardiac Output (APCO)
Dynamic Response Test
Zeroing
Arterial BP
5
Measurement of CO adjusted for BSA
Cardiac Index (CI)
Stoke Volume (SV)
Stoke Volume Index (SVI)
Cardiac Output (CO)
6
Avoiding Complications: Assess hourly (issue if cool, pale skin w/cap refill longer than 3 secs) loss of limb?=emergency
Infection
Neurovascular Status
Hemorrhage
7
Measurement of SV adjusted for BSA
Cardiac Output (CO)
Cardiac Index (CI)
Stoke Volume Index (SVI)
Stoke Volume (SV)
8
normal O2 supply & metabolic demand
Normal ScvO2 or SvO2 (60-80%)
High ScvO2 or SvO2 (80-95%)
Low ScvO2 or SvO2 (<60%)
9
Confirm when pressure w/in system is zero (stop stopcock to RA off pt) observe for 0 reading
Arterial Pressure Based Cardiac Output (APCO)
Dynamic Response Test
Arterial BP
Zeroing
10
opposition
encountered by LEFT ventricle
Pulmonary Vascular Resistance (PVR)
Systematic Vascular Resistance (SVR)
11
If hand does not return to pinkness w/in 6 secs it is okay to insert because the ulnar artery circulation is adequate
True
False
12
Body surface Area is more precise measuremnt of efficiency of <3 pumping action(left& right ventricle pump at same time)
False
True
13
Checking equipment reproduces w/o distorted signal. Perform every 8-12hrs when system open to air (start flash flush)
Arterial BP
Dynamic Response Test
Zeroing
Arterial Pressure Based Cardiac Output (APCO)
14
^ctrx force ^ & ^SV &CO =greater <3 stretch & O2 requirement, ^CO + this = ^ O2 delievery
Preload decreases
Afterload Increases
Preload Increases
Afterload decreases
15
systolic BP + 2(diastolic BP) divided by 3
Afterload
Preload
MAP Equation
Contractility
16
opposition
encountered by RIGHT ventricle
Systematic Vascular Resistance (SVR)
Pulmonary Vascular Resistance (PVR)
17
Avoiding Complications: Use Luer-Lok connections, always check waveform, & activate alarms (prevent dislodgement)
Infection
Hemorrhage
Neurovascular Status
18
CO can be improved by myocardial O2 needs reduced by _____
Afterload decreases
Afterload Increases
Preload decreases
Preload Increases
19
Helps determine adequacy of tissue oxygenation & indicates balance b/w O2 delievery & O2 consumption
Venous Oxygen Saturation Monitoring
Pulmonary Artery Flow-Directed Catheter
20
Maintaing Arterial BP Line Patency & Limit Thrombus Formation:
System delivering continous slow (1-3mL/hr flush
Flush bag contains fluid
Assess every 1-4hrs
Pressure bag inflated 300 mmHg
21
decrease O2 supply caused by ^O2 demand & decreased hemoglobin, CO, & arterial saturation (SaO2)
Normal ScvO2 or SvO2 (60-80%)
Low ScvO2 or SvO2 (<60%)
High ScvO2 or SvO2 (80-95%)
22
Increase O2 supply decrease O2 demand (may indicate clincial improvement)
Normal ScvO2 or SvO2 (60-80%)
Low ScvO2 or SvO2 (<60%)
High ScvO2 or SvO2 (80-95%)
23
You should NOT perform an Allen Test before inserting a line in the radial artery
False
True
24
Increase = decrease CO & increase O2 demand
Afterload Increases
Preload decreases
Afterload decreases
Preload Increases
25
Safety Alert: Positioning the Zero Reference Stopcock
Transducers HIGHER THAN PT produce a LOW BP
Recheck lvling of zero refernece stopcock to PA w/any change in pt position
Mark location of phelobostatic axis on pt chest w/permanent marker
Transducers LOWER THAN PT produce a HIGH BP
26
FORCES opposing ventricular ejection
Preload
Contractility
Afterload
MAP Equation
27
volume of blood w/in ventricle @ END of DIASTOLE
Preload
MAP Equation
Contractility
Afterload
28
Volume ejected w/each heartbeat
Cardiac Output (CO)
Cardiac Index (CI)
Stoke Volume Index (SVI)
Stoke Volume (SV)
29
strength of ventricular ctrx. ^= ^SV & O2 requirement. Preload, HR. & afterload constant & CO changes, decrease in this
Afterload
Contractility
Preload
MAP Equation
30
Avoiding Complications: Monitor S/S of infection (Change pressure tubing, flush bag, & transducer every 96hrs)
Infection
Hemorrhage
Neurovascular Status
31
diuresis & vasodilation decrease this
Preload decreases
Afterload Increases
Afterload decreases
Preload Increases