A parallel-type electrical circuit is one in which the
A Pittsburgh seam is used to join metal
HVAC prep 2
30 terms
·
StudBud Administration
·
174 plays
x
Flashcards
30 cards
F
Practice quiz
P
Host live
L
Questions
30
Answers
1
A Pittsburgh seam is used to join metal
sections of round pipe
tap collars to truck
on a flat surface
at a 90-degree angle
2
A parallel-type electrical circuit is one in which the
total curent is ÷ between each individual load or resistance
resistance is = to the voltage multiplied by the amperaget
total flow thru each and every resistance load individualy
voltage is equal to the amperage divided by the resistance
3
Multi-compressor systems require
a single start relay
sequencing control systems
start capacitor banks
defrost controls
4
a refrigeration system containing oil should never be pressurized with
nitrogen
dry nitrogen
oxygen
refrigerant
5
a overcharge of refrigerant a cooling/refrigeration system will cause
low head pressure
low suction pressure
the compressor to run faster
high head pressure
6
incomplete combustion results from a lack of
Carbon monoxide
Oxygen
Fuel
Carbon Dioxide
7
The t stat terminal the indoor fan circuit on a heat pump is the ___ terminal
G
C
W
F
8
A drawing used to see the mounting height of a register on a wall is a
pictorial diagram
elevation
floor plan
site plan
9
when refrigerant is added to an air conditioner
suction pressure will decrease and subcooling will decrease
suction pressure will decrease and subcooling will increase
discharge psi will decrease and subcooling will increase
discharge pressure will increase and subcooling increase
10
The unit for flow of electricity is the
Ampere
WattV
BTU
Volt
11
CSST (corrugated stainless steel tubing) can
only be installed in horizonal applications
not be installed in propane applications
be combined with black iron steel piping
only be installed in exterior applications
12
this tool is called a
sawzall
plungesaw
jab-saw
jigsaw
13
when working with a power tool with 90 decibels and higher, the tech should wear safely glass &
a safety harness
steel toe boots
a hard hat
ear protection
14
Name of the device that is used to remove small air bubbles in the hydronic pipping system?
water separator
air separator
Flow control separator
Mass flow separator
15
Working on voltage equipment ,service tech are more likely to receive electrical shock when
Performing the work at the beginning of the work day
working in damp or wet locations
all equipment has been locked out and tagged accordingly
repairs on 24 volt control circuits
16
Hydronics is the science of
refrigeration study
heating with water
pneumatics
gas furnace
17
This tool is called a
Ratchet wrench
Refrigerant Wrench
Square box wrench
Adjustable wrench
18
When using a ladder around electrical line, the worker should
use wooden stand offs
make sure the ladder has a good base
not use a metal ladder
wrap ladder in rags
19
A 90-degree PVC elbow that has both a male and female connection is called a
four-way fitting
coupling
street fitting
union fitting
20
A pulsating sound in an oil burner indicates that the
Flame is touching the sides of the combustion chamber
igniter is set too high
water in the system is too hot
flame is yellow and needs air
21
after installation the tech needs to ____ before turning on/firing the oil or gas burner
purge all the air from the system and dry fire the unit
inform the customer
turn on power
purge air from the system and fill with H2O to 10-15 psig
22
An HVAC system may be controlled by a/an
fossil fuel kit
solar-powered generator
programable fan relay
internet-based application
23
In series circuit, the total current is equal to
the amount determine by the formula
a sum of currents through each resistance load
the total Resistance divided by the total voltage
the current measured at any place in the circuit
24
high voltage connected to the a low voltage sequencer coil will
cause the coil to have a stronger magnetic pull
cause the sequencer to work faster
damage the coil
not a damage the coil
25
This symbol represent a _____ in an electrical schematic
low pressure switch
high pressure switch
cooling thermostat
heating thermostat
26
The formula for computing power consumption (watts) in an AC circuit is
power=E/I
power=I x E x R
power=I x E
power= E/IxR
27
Most 90 percent-plus-efficient natural gas furnaces use an ignition device called a/an
thermocouple
Mercury filled thermometer
standing pilot
hot surface ignitor
28
A CAP tube system isn't working properly. Ice built up from evap to comp whats wrong w/ system?
Compressor is running backwards
compressor is not running
system is undercharge
system is overcharged
29
Frost accumulating on the evaporator coil of an air condition system is caused by
high superheat across the coil
excessive charge of refrigerant
low air flow across the coil
excuses air flow across the coil
30
A supply plenum is mounted
air earth register
on the top of an up-floe furnace
on an air handler nearest the blower