Most propane appliances require an input pressure of around _____" w.c., or about ½ lb of pressure.
3.5
100
6
11
2
2nd stage regularos have a flow capacity to meet the total gas demand of all the appliances connected to the regulator.
False
True
3
When reading the dials of a circular index, start with
furthest to the right and proceed left
anywhere, because it doesn’t matter
in the center and proceed outward
furthest to the left and proceed right
4
To prevent regulator freeze-up due to vent blockage the regulator should be mounted so that the ___
diaphragm points upward
regulator points downward
vent points downward
vent points upward
5
Do
not
adjust a regulator until you have been trained how to do so.
False
True
6
_____ show the capacity of a regulator at different delivery pressures given the factory setting for outlet pressure.
Regulator performance curves
Linear Capacity chart
Delivery Pressure cake chart
Regulator Sizing chart
7
Which of the following is
not
a factor to consider when selecting a regulator?
Total gas demand
Manufacturer’s information
Customer preferences
Pressure requirements
8
To select the appropriate 2nd stage regulator, you will need to consider
All the above
Outlet pressure
Inlet pressure
Total gas demand
9
Natural gas has more btus per cubic foot than propane
False
True
10
Effective , ____NFPA 58 prohibits the installation of single-stage regulators in residential central heating systems.
June 30, 1986
June 30, 1997
June 30, 2000
June 30, 1991
11
NFPA 58 States :The relief valve for a single-stage regulator may be the same as for a second-stage regulator.
True
False
12
Natural gas meters are more widely used than propane meters.
False
True
13
The delivery pressure of the first-stage regulators is set at the factory and is typically __________.
1000 psig
100 psig
2 psig
10 psig
14
Vapor meters are not affected by both the gas pressure inside the meter and the atmospheric pressure on the outside.
False
True
15
what is a factor to consider when designing a second-stage regulator system?
Appliance demand
Special requirements
All The above
Piping layout
16
For residential & small commercial propane applications, system delivery for appliance inlet pressure typically _____
3.5" to 5" w.c.
2 psig to 10 psig
10.5" to 14" w.c.
100 psig to 400 psig
17
When 2+are installed in the same location, NFPA 54 requires that each meter be tagged to indicate the specific customer.
False
True
18
Do
not
attempt to change the setting of a regulator relief valve.
False
True
19
When sizing vapor meters for ½ lb systems, select the meter according to its capacity at 2" w.c. pressure drop.
True
False
20
Most propane vapor meters are designed to operate with an inlet pressure of ________
11" water column
2 psig
3.5" water column
100 psig
21
The regulator should be constructed of materials that are compatible with LP-gas service and the external environment.
True
False
22
Regulator selection is based on _______________.
downstream gas demand and service technician requirements
downstream gas demand and flow capacity
downstream gas demand and regulator components
appliance operating pressure and regulator components
23
The inlet pressure for a
first-stage regulator
is determined by the
container pressure
Outlet pressure of the 2nd stage regulator
Phases of the moon ( Tidal Force)_
Appliance Demand
24
Btu/hr demand of the appliances will not affect the piping layout, size and number of gas piping entry points required.
False
True
25
When planning an installation, the meter must be plumb and level in all directions.
True
False
26
210 CFH of natural gas =____ CFH of propane
210
2500
132
333.33
27
Vapor meters have ______ formed by a ____ diaphragm.
fixed-volume measurement compartments, one-sided
fixed-volume measurement compartments, two-sided
multi-volume measurement compartments, two-sided
compound-volume measurement compartments, two-sided
28
___________ are pre-assembled units designed to connect gas meters to supply piping.
Meter Connectors
Pipe Blocks
Meter bars
Assembley Hangers