stud
bud
Sign up
Log in
Home
Library
Explore
SAT
More
SPD 102 Final review Flashcards | StudBud
Explore
/
SPD 102 Final review
SPD 102 Final review
81 terms
·
StudBud Administration
·
25 plays
Imported from external platform
Flashcards
81 cards
F
Practice quiz
P
Host live
L
Questions
81
Answers
1
Instruments are heat treated to give their surface a mirror (shiny] finish.
False
True
2
When Central Service technicians have internet access at work
it should only be used during break time.
it should be used for work-related purposes only.
they should follow the facility's policy.
it may be used for any purposes as long as it doesn't interfere with work.
3
Central Service technicians who do not think they are being treated appropriately by their employer should
discuss the situation with their supervisor.
accept the situation as "the way things are done" at the facility.
find another job.
discuss the problem with their workplace peers.
4
Which of the following statements about endoscopes is true?
Not all endoscopes can be processed in an automatic endoscope reprocessor.
Ultrasonic cleaning is the process of choice for endoscopes.
Flexible endoscopes are not easily damaged.
All endoscopes should be steam sterilized.
5
Gauze squares are the wicking material of choice for instrument sets.
False
True
6
The purpose of a suction stylet is to
unclog the suction during surgery
provide a measuring guide for the surgeon.
clean the suction in the decontamination area.
facilitate the sterilization process.
7
Disposable components such as pads and tubing on patient care equipment should be
removed in the biomedical engineering department.
discarded during preventive maintenance
be reprocessed for re-use.
discarded at the point-of-use.
8
Technicians in the ______ department perform safety inspections and functional tests on equipment.
facilities and maintenance
Biomedical/Clinical Engineering
Materiel Management
infection control
9
Knowing what is expected and consistently meeting those expectations is part of
effective communications
ethical behavior.
professional behavior.
job success
10
The U.S. Food and Drug Administration classifies sterilization packaging as a
Class I Medical Device
Class IV Medical Device
Class III Medical Device
Class II Medical Device
11
Count sheets
include manufacturer's Instructions for Use information.
provide a detailed list of tray contents.
are used only for Operating Room trays and large procedure packs
describe each instrument in detail.
12
The place where the two parts of a ring handled instrument meet and pivot is called the box lock.
True
False
13
When transporting items that have been immediate use steam sterilized, it is required that they be
transported to the patient area within five minutes of the completion
transported in such a manner that reduces the chance for contamination
allow to properly cooled before transport.
transported in a metal container
14
Using latex tubing to protect delicate instrumentation is the process of choice for items to be steam sterilized.
True
False
15
When sterilizing items at the point-of-use, an abbreviated cleaning procedure may be used due to the urgent need for the
False
True
16
Patient care equipment should be stored in a _______ condition.
"ready to clean"
"ready to sterilize"
"ready to dispense"
"ready to inspect"
17
Coaching is an example of
discipline.
informal communication
formal communication
Mentoring.
18
When speaking, one should
use technical jargon to impress the listener.
concentrate on oneself rather than the listener.
concentrate on the listener rather than oneself.
be influenced by the listener's emotions
19
You are enjoying taking class online
False
True
20
Loaner instruments should
should not be used.
be sterilized using a low temperature process.
be decontaminated before use
be decontaminated if they appear soiled upon arrival.
21
To properly test the sharpness of scissors four inches or less use
yellow test material.
an index cart
orange test material.
red test material.
22
All flexible endoscopes have internal channels.
False
True
23
The endoscope that would be dispensed for a procedure to visualization of the lower part of the large intestine.
sigmoidoscope.
colonoscope.
gastroscope.
ureteroscope.
24
Which of the following is NOT an acceptable sterilization packaging material?
Muslin
Barrier cloth
Twills
Canvas
25
Temperatures in a sterile storage area should be 55°F to 60°F.
True
False
26
Which of the following is an example of communication?
Written word
All of the above
Spoken word
Non-verbal expressions
27
Instrument marking tape should be wrapped approximately ______ around the instrument
2.5 times
1.5 times
three times
two times
28
An osteotome is
a hemostatic forceps.
a retractor.
used to dissect soft tissue.
used to cut or shave bone.
29
When placing instruments in a peel pack, the tips should always face the plastic side of the pack.
True
False
30
The best way to transport items that have been processed using immediate use steam sterilization at the point of use is
in a covered mesh bottom tray.
covered with a sterile towel.
in a kraft paper bag
in a rigid container designed for immediate use steam sterilization.
31
After applying instrument identification tape, instruments should be autoclaved to help the tape bond to the instrument.
False
True
32
When placing hinged instruments in an instrument tray
arrange the instruments in the order of their use.
lock the handles to prevent damage during sterilization.
arrange the instruments in alphabetical order.
unlock the handles and open the instruments
33
If an equipment malfunction causes harm to patients, it should be
sent to the manufacturer for repairs
returned immediately to the Biomedical department.
discarded immediately
sequestered for inspection by OSHA personnel
34
Tissue forceps have teeth.
False
True
35
During instrument manufacture the process of passivation helps build a protective chromium oxide layer on each instr.
True
False
36
Electronic testing of laparoscopic insulation should be done?
in the decontamination area prior to cleaning.
in the clean assembly area prior to set assembly
in the Operating Room at the end of the procedure.
at the factory or onsite repair unit.
37
Before an item can be placed in a liquid chemical sterile processing system they must be.
sterilized.
filled with air.
heated.
cleaned.
38
The relative humidity of the Central Service prep and pack area should be
40% to 80%
30% to 60%.
less than 75%
less than 35%
39
Both the Association of periOperative Registered Nurses and The Joint Commission recommend that
the use of immediate use steam sterilization be minimized or decreased.
IUSS be performed in only one sterilizer per facility
only Central Service technicians operate immediate use steam sterilizers.
healthcare facilities get FDA approval for immediate use steam sterilizatio
40
Which of the following statements is correct?
Employees can only be members of one formal group at a time
Informal work groups are "bad" for the organization
A task group is an example of an informal group
Informal groups develop an informal communication called the grape vine
41
Stainless steel jaw needle holders last longer than tungsten carbide jaw needle holders.
True
False
42
A step in communication that occurs when a listener asks a question is called
communication looping.
stereotyping.
feedback.
halo interpretation.
43
The ability to use information gained from words or body language to interact with others.
Teamwork
Human relations
Mentoring
Communication
44
The best way to clean a suction lumen is
soaking in an enzyme solution for three minutes
using the appropriate stylet
using the proper sized brush.
using running warm water.
45
Flexible endoscopes that fail a leak test may continue to be used until the break/hole impacts the scope's function.
True
False
46
This process allows a person to understand someone else's needs
Feedback
Communication
Human relations
Moral behavior
47
Which of the following basic listening tactics is most useful?
None of the above
Ignore any non-verbal communication "sent" by the speaker
Focus on the delivery of the message rather than its content
Try to listen only for specific facts
48
The part of a hemostat that locks and holds it in position is called the box lock.
True
False
49
The decision to use reusable or disposable instruments in procedure trays is determined by
several factors including physician preference, storage and cost.
the Infection Prevention department
where the instruments will be used.
amount of items to be used and delivery schedule
50
When patient equipment enters a healthcare facility, it must be safety checked by?
infection control committee membe
Central Service directo
Central Service technician
Biomedical technician
51
All patient care equipment that was dispensed for use must be Considered?
visibly soiled
clean
sterile
contaminated
52
Preventive maintenance is
performed when a piece of equipment injures a patient.
performed when a user unit notices a problem.
designed to identify potential problems before they occur.
done by Central Service before equipment is dispensed.
53
Behavior relating to what is "right" and "wrong" relative to the standards of professional conduct are called
ethical behavior.
personal behavior
legal behavior
moral behavior
54
Endoscopes are often processed in a mechanical unit called
an ultrasonic cleaner.
a washer-decontaminator.
an automatic endoscope reprocessor.
a flush-pulse endoscope reprocessor.
55
Which of the these should be used to thoroughly rinse (remove] all traces of disinfectant from an endoscope's channels?
Water containing approved sterilant
Treated water
Forced air
A heated glutaraldehyde
56
The first step to inspect the insulation of a laparoscopic instrument is to
try to slide the insulation back.
check the handle for chipping or cracking.
visually check the instrument's shaft.
check the collar at the distal tip.
57
Equipment should be inspected for obvious hazards such as cracked or frayed electrical cords
only by trained biomedical engineering technicians.
only during preventive maintenance activitie
whenever the equipment is inspected in Central Service.
only when there are complaints from user department personnel.
58
When arranging paper/plastic pouches in the sterilizer; the pouches should be arranged
flat.
paper-to-plastic.
paper-to-paper.
plastic-to-plastic
59
After use, loaner instrumentation must be decontaminated before it is shipped out.
True
False
60
The purpose of using a decontamination battery or hose when cleaning powered surgical instruments is
to keep functioning batteries and cords clean.
to prevent electrical shock.
to test the unit while cleaning.
to keep fluid from entering the unit.
61
The biggest advantage to battery-powered surgical instruments is that they can be immersed for cleaning.
True
False
62
Which of the following is the most important factor necessary for teamwork?
Loyalty
Attitude
Cooperation
Promptness
63
Loaner instrumentation can cause receiving challenges.
True
False
64
Information regarding cleaning processes for endoscopes should be provided by
the Operating Room staff.
the instrument manufacturer.
the Association for Professionals in Infection Control and Epidemiology.
the Society of Gastroenterology Nurses and Associates.
65
Scissors with tungsten carbide cutting edges are usually identified by
silver handles
gold handles
the letters "TC".
black handles
66
All instruments must be dry before sterilization it is important to ensure all lumens are kept moist for sterilization.
False
True
67
Which of the following requires that preventive maintenance standards be established for medical equipment?
National Institute for Occupational Safety and Health
The Joint Commission
Occupational Safety and Health Administration
Association for the Advancement of Medical Instrumentation
68
Employees from different departments within the healthcare facility that work together to solve operating problems is a?
multi-dimensional team.
cross-functional team.
decision-making team.
management/sub-management team.
69
Reusable textile packaging requires less labor than disposable packaging.
False
True
70
Microgrind or supercut scissors are usually identified with a black handle.
False
True
71
Cellulose materials cannot be processed within ozone sterilizers.
False
True
72
Kerrison/laminectomy rongeurs should be tested using
tissue paper.
a plastic dowel rod.
rubber testing material.
an index card
73
Which of the following steps happens first when processing flexible endoscopes?
Drying
Manual cleaning
Leak-testing
High-level disinfecting/sterilizing
74
Which of the following statements is correct?
Environmental Protection Agency Patient Security Act
leasing involves purchase; rental does not require ownership
Tracking patient care equipment can prevent equipment shortages
Patient care equipment tracking requires a computer
75
Which of the following is true about a valuing diversity effort?
It is a "program" in which a committee "decides what to do"
It occurs because a Central Service director desires it
None of the above
It "happens" because top-level officials require it
76
Some plastics including formulations of spun-bonded polyolefin are intended for use solely in what sterilization process
steam.
ozone and hydrogen peroxide.
liquid.
gravity.
77
Immediate use steam sterilization documentation should include
all the above.
the name of the patient for which the items were sterilized.
name of the instrument sterilized
sterilizer number and cycle.
78
The process by which instruments are steam sterilized for immediate use is called
emergency sterilization.
immediate use steam sterilization.
rapid reprocessing.
core sterilization.
79
All rigid sterilization containers have tamper-evident seals.
True
False
80
Name the patient care equipment limits the development of deep vein thrombosis and peripheral edema in immobile patients
Defibrillator
Sequential compression devic
Respirator
Intermittent suction device
81
Items to be disinfected or sterilized at the point of use must be
non-critical devices.
heat sensitive
properly cleaned per Manufacturer's Instructions for Use.
semi-critical devices