The preset-time mode on a counter is:
Controlled by the operator
Controlled by the coincidence timing window
Controlled by a timer circuit
Controlled by an external timer or sample changer assembly
2
All of the following are true regarding oscilliscopes EXCEPT:
Allows many pulses to be viewed simultaneously
Modern day equipment utilize digital oscilloscopes
Displays used are flat-panel liquid crystal
Measures the distribution of energies deposited in the radiation detector
3
Rate meter time constant is determined by multplying the rate at which the charge discharges through the resistor(R) &:
Frequency (F)
Charge deposited on the capcitator (C)
Direct Current (DC)
Alternating Current (AC)
4
The maximum time interval between two pulses for them to be counted as being in coincidence is referred to as the:
Sacler Gate
Coincidence Timing Window
Analog Rate Meter
Voltage Ripple
5
____ control the scaler counting time
Modern Scalers
Scalers
Timers
Oscilliscope
6
___ measures the distribution of energies deposited in the radiation detector.
Oscilliscope
Single Channel Analyzer
Multi-Channel Analyzer
Coincidence Unit
7
The____converts the alternating current (AC) voltage provided by the line source into a direct current (DC) voltage
Coincidence Unit
Scaler-Timer
High-Voltage Power Supply
Oscilliscope
8
Each decimal counter assembly in a counter records from zero to nine events
False
True
9
___produces an output signal with a voltage proportional to the time difference btw 2 logic pulses supplied to the input
Time-to-Amplitude Converter
Scaler Gate
Scaler-Timers
Oscilliscope
10
The generic name for scaler-timers is:
Counters
Scalers
MCA
Scaler Gate
11
___ refers to the voltage varying which can result in image noise and image degradation
Coincidence Timing Window
Rate Meter Time Constant
Voltage Ripple
Alternating Current (AC)
12
The high-voltage power supply provides charge collection to all of the following EXCEPT:
Semiconductor Detectors
Dosimeters
Geiger-Muller Detectors
PM tubes
13
___ identifies the two-way coincidence events resulting from annihilation photons in PET
Analog Rate Meters
High-Voltage Power Supplies
Oscilliscopes
Coincidence Units
14
___ is an instrument that incorporates both scalers and timers in a single unit.
Sclaers
Timers
Time-to-Amplitude Converter
Scaler-Timer
15
PET imaging commonly utilizes coincidence units for image acquisition
True
False
16
Most modern scalers are capable of ____ MHz counting rates
20-50
20-70
30-50
10-40
17
___ utilizes a Start and Stop signal.
Oscilliscope
Coincidence Unit
TAC
Single Channel Anlyzer
18
The ___ pulse resets the counter assembly to zero and sends a pulse to the next DCA in the series
15th
9th
10th
1st