Test 2 Flashcards | StudBud
Explore
/
Test 2
Test 2
85 terms
·
StudBud Administration
·
22 plays
Imported from external platform
Flashcards
85 cards
F
Practice quiz
P
Host live
L
Questions
85
Answers
1
To receive information for display at a rapid rate, it is desirable to use a ________.
high pulse repetition frequency
lower operating frequency
high operating frequency
low pulse repetition frequency
2
Even unfocused transducers have a natural focus.
False
True
3
The matching layer increases reflection of the transducer element.
True
False
4
Detection is also called demodulation.
False
True
5
Gain is the ratio of __________.
amplifier input to output voltage power
transmission output to amplifier input
voltage ratio squared or voltage ratio to the second power
amplifier output to input electric power
6
Wide bandwidth allows harmonic imaging.
True
False
7
lateral resolutions remains consistent at any depth
False
True
8
Intravascular imaging generally utilizes a frequency range ________.
up to 50 MHz
between 10 and 15 MHz
between 5.0 and 7.5 MHz
between 2.5 and 5.0 MHz
9
lateral resol/2 ution is equal to ____
wavelength /2
beam width
spatial pulse length / 2
operating frequency/2
10
Which of the following constitutes a reception channel?
elements, pulser, signal processor, and delay path
Beam former, pulser, amplifier, and scan converter
Elements, amplifier, digitizer, and delay path.
Beam former, signal processor, image processor, and display.
11
A flat-panel display presents image information in the form of ________.
horizontal lines read out from right to left
vertical lines read out from left to right
vertical lines read out from right to left
horizontal lines read out from left to right
12
Focusing in the section thickness plane reduces section thickness artifact.
True
False
13
The ________ is the number of sonographic images entered into memory per second.
cine loop
image refresh rate
pulse repetition frequency
frame rate
14
Which of the following digitally filters, detects, and compresses echo data?
beam former
signal processor
summer
digitizer
15
Various formulations of lead zirconate titanate are commonly used in modern day transducers.
True
False
16
Which of the following reformats data into image form for processing, storage, and display?
signal processor
beam former
digitizer
summer
17
look at the picture below
True
False
18
Utilizing additional focal points causes the temporal resolution to __________.
degrade
improve
remain unchanged
double
19
How many bits does it take to make a byte?
8
10
15
4
20
In a single-element transducer, additional beams not included in the ultrasound beam are called _____________.
side lobes
slice thickness
scattering
grating lobes
21
Which of the following frequencies is operated by the thinnest element?
7.5 MHz
10 MHz
2.5 MHz
3.5 MHz
22
Coupling medium is applied to the transducer–tissue boundary to increase _________ of the sound wave.
transmission
refraction
scattering
reflection
23
Linear and convex are types of ________ arrays.
focusing
scanning
operation
assembly
24
A digitizer _______________
directs the driving voltages from the pulser
converts voltage from analog to digital form
compensates for attenuation
is responsible for the focusing and steering functions
25
The operating frequency depends on the element propagation speed and thickness
False
True
26
Which of the following is
not
an advantage of harmonic imaging?
elimination of grating lobes
increase lateral resolution
reduction in superficial reverberation artifacts
wide primary beam
27
When gain is too high, which of the following occurs?
weak echoes are not imaged
contrast resolution is improved
temporal resolution is reduced
differences in echo strength are lost
28
Human vision is limited to a dynamic range of about 30 dB.
True
False
29
Which of the following describes the far zone?
the length of the far zone increases in frequency
it lies within one near-zone length
it is called the fresnel zone
its beam width (diameter) increases with increasing depth
30
The averaging of sequential frames together to provide a smoother image appearance is called ________.
pixel interpolation
persistence
spatial compounding
multi-focus
31
Without compensation the ultrasound transducer would cause about ____ of the emitted intensity to be reflected by skin
10%
25%
80%
50%
32
The distance from the transducer to the center of the focal region is called the ________.
focal length
focus
path length
focal-zone length
33
The ________ and ________ determine the maximum imaging depth.
transducer element; propagation speed
minimum amplifier gain; attenuation
attenuation; maximum amplifier gain
operating frequency; propagation speed
34
An increase in the number of channels ________.
allows more precise control of the beam characteristics
decreases the control of the beam characteristics
increases exposure intensity to the patient
increases the thickness of the transducer element
35
Which image format is similar to that for convex array except that the footprint is smaller?
interventional
vector
sector
curvilinear
36
The ________ drive(s) the transducer forming the beam that sweeps through the tissue to be imaged.
channels
beam profiler
coded excitation
pulser
37
Multi-Hertz transducers are driven at only one selectable frequency.
True
False
38
you find this lymph node Which sonographic term listed below is the best to describe it?
hyper echoic
echogenic
hypoechoic
caclific
39
answer question below
A (amplitude)-mode
C (color)-mode
M (motion)-mode
B (brightness)-mode
40
image displays the carotid bifurcation. The ECA is most likely
the lateral vessel
the medial vessel
41
Principle 2 virtual beam forming greatly improves axial/elevational resolution compared to resolutions in Principle 1
False
True
42
Brightness mode is also called ________.
B color
volume imaging
elastography
gray-scale
43
Intensity of the echo information is stored as binary numbers in memory elements.
False
True
44
The pulse repetition frequency (PRF) in real time imaging typically ranges from ________.
4-15MHz
2-15 MHz
2-20MHz
5-50 MHz
45
in a curved array, the pulses travel ___
in straight lines
faster in the center of the beam
from an apex
out in different directions
46
Contrast resolution depends on ________ of bits per pixel.
number
size
strength
configuration
47
With a linear phased array transducer, the elements measure the width of about ________.
one quarter of a wave length
two wavelength
one wavelength
one half of a wavelength
48
M (motion)-mode is a presentation of echo depth versus time.
False
True
49
Storage of the last several frames acquired before freezing is called ________.
cine loop
freeze
picture archiving
triplex
50
The transducer has an impedance ______ times that of tissue.
4
10
6
20
51
Improvements in Principle 2 virtual beam forming include reduced section thickness, which improves _______.
axial resolution
elevational resolution
lateral resolution
all are correct
52
answer question below
transmit/recieve (T/R) switch
signal
channels
beam former
53
Beam width can be reduced by focusing to improve lateral resolution.
False
True
54
Sonographic systems with ______ technology can identify certain normal/abnormal tissue types and label them on the image
harmonics imaging
spatial compounding
elastography
artificial intelligence
55
Arrays have additional beams resulting from their multi-element structure called ________.
speckle
refraction
grating lobes
side lobes
56
The near-zone length decreases with an increase in frequency.
False
True
57
Temporal resolution in M (motion) and A (amplitude) modes is equal to the pulse repetition period (PRP).
False
True
58
Another name for the Fresnel zone is ________________.
field zone
near path zone
field length
near zone
59
Which system component produces the electrical voltages that drive the transducer?
piezoelectric element
summer
pulser
digitizer
60
which system control equalizes amplitude by different reflector depths?
persistence
compensation
overall gain
time gain compensation
61
Each independent delay and element combination constitutes a transmission channel.
False
True
62
The dimension perpendicular to the scan plane is called ________.
side lobes
grating lobes
section thickness
Variable aperture
63
The ________ is where the action originates.
beam former
code excitation
signal processor
transit/receive (T/R) switch
64
The useful frequency range for most diagnostic applications is ____________ MHz.
2-20
1-50
2-15
1-15
65
Panoramic imaging expands the image ________.
quality, allowing for a much smoother image
beyond the normal limits of a transducer
resolution
by using a special panoramic transducer
66
Which of the following determines the beam width at the focus?
spatial pulse length and prop speed of the element
aperture, focal length, and wavelength
focal length and frequency
aperture, propagation speed and thickness
67
The critical temperature an ultrasound transducer cannot exceed is called the ________.
critical point
curie point
quality factors
piezoelectric point
68
prop speed of the transducer element material is 6 mm/µs, the operating frequency for a thickness of 0.2 mm is _____ MHz
7.5
30
12
15
69
The conversion of echo voltages from the radio frequency to video form is called ________.
analog-to-digital conversion
scan conversion
demodulation
pulse inversion
70
Normally the number of channels does not exceed the number of ________.
pulse delays
ultrasound pulses
cycles per second
elements in the transducer
71
Damping material in pulsed transducers increases the spatial pulse length.
True
False
72
The near-zone length is determined by the size and the _________ of the element.
thickness
prop speed
operating frequency
all are correct
73
Which of the following operator controls adjusts compression?
dynamic range
depth
time gain compensation
overall gain
74
The three aspects of imaging resolution include axial, contrast, and temporal resolution.
False
True
75
Maximum amplifier gain is determined by ________.
manufacturer
noise
output
input
76
To avoid echo misplacement ________.
all echoes must be received before another pulse is emitted
penetration depth is increased
a matching layer is added to the transducer element
multiple focal zones should be utilized
77
averaging sequential frames improves
frame rate
temporal resolution
dynamic range
penetration depth
78
Shortening the pulses in diagnostic ultrasound broadens the ______________.
lateral resolution
bandwidth
duty factor
pulse duration
79
The beam former amplifiers typically have ________ dB of gain.
50-100
30-60
30-100
60-100
80
All of the following are examples of postprocessing except _____.
volume presentation
read zoom
write zoom
b color
81
Axial resolution is the ________.
min. separation to resolve reflectors perpendicular to the beam direction
ability to differentiate a moment in time
ability to differentiate similar and dissimilar tissue
minimum speration necessary to resolve reflectors along the scan line
82
Increasing the frame rate improves ________.
temporal resolution
detail resolution
penetration depth
axial resolution
83
Filtering of the sound beam is used to eliminate ________.
side lobes artifacts
frequencies outside of the bandwidth
the fundamental frequency
secondary frequencies
84
Pixel interpolation, persistence, and panoramic imaging are examples of ________.
spatial compounding
signal processing
preprocessing
postprocessing
85
With phasing, the reception beam is ________ and dynamically ________.
focused; steered
generated; recieved
variable; focused
steered; focused