When
replacing
a defective component what application must we use AFTER Server Repair Check-in?
Server Repair Check-out
Msft gen6 Rack Assistant
Rack Repair Check-in
2
Commands sent to Microsoft Servers running Windows, Amazon Servers, and Rack managers are universal across
ALL
Servers
True
False
3
What is
Not
a Role/Responsibility you will be expected to do?
Maintaining a safe and clean work area
Removal of heavy components
Implementing Scripts to the test flow
Assisting with adding/removing racks
4
What OS is run on ZT servers?
Linux
Windows
All of the above
5
Which of the following is true about the Rack Shipment Travler?
Is located in a pouch attached to the right side of the rack's frame
All of the above
List of required job tasks from each area that requires signatures
Contains shipment information about the rack
6
Is it Safe to service a server at the top of the rack when most servers on the bottom half of the rack are empty?
Yes, as long as you are using a ladder
No, the rack does not have enough counterweight toward the bottom.
7
When
replacing
a damaged component what ticket must be filled out before heading to MRS/Part Runner?
Defective Item Traveler (Green Ticket)
Unusable Item Traveler (Cream Ticket)
No Ticket, bring part to MRS/Part Runner
Send MRS a message on Microsoft Teams
8
For Amazon Racks, Power is sent to the units through the
Powershelf bus bar
True
False
9
To see all
checkpoints
of a unit throughout its LIFE CYCLE on the production floor, what application do you use on MES?
Product Status
Job Detail Report
Product History
10
Before opening a Server, The Server Assembly Manual SOP can be a guide on how to assemble and disassemble the server
True
False
11
What should you do when you receive a
suspicious email with a link or attachment?
Open the Link or attachment to confirm the suspicion
Click the Phishing Alert button to report it to IT Cyber Security team.
Forward the Email withe the link to Eveyrone on your shift
12
Verizon Servers may be populated into a test rack since they are handled individually
False
True
13
Patch Panels are used to provide network to the rack via fiber Or Cat6 Cables
False
True
14
When a server fails for a defective component what must be done first?
Server Repair Check-out
Identify the failure, Check the logs, Server Repair Check-in
Server Repair Check-in
15
What Tests are part of the
Pre Burn-in Flow?
All of the above
CTCS, MdaSS, OQT
Assembly-Z, Updates, Pre-Z
16
When a Server needs a specific Test Reset, techs should post in the Teams chat to ask a champion for approval
False
True
17
Once a Server has passed Server Level Testing and has been confirmed as Final-Z Conform Pass on MES what do you do next?
Unplug all the network cables from the server
Place a Final ZC/QC Pass label on the server
Reboot the Server
18
If for any reason an employee's badge is missing or needs to be replaced, what should you do?
Don't come in for your shift
Contact your Manager and Security so you can be issued a Temp ID.
Your State-issued ID will get you through Security
19
Other than Managers, Supervisors, Safety and Quality teams: Are techs allowed to take photographs?
Photographs are prohibited
Only if you send it through Microsoft Teams
Only if you don't post it online
20
When a new
Rack
is put into a Slot where you're working what's the
first
thing to do?
Server-level Test Check-in
Physical Inspection
Remote into a server
21
When the
Power Source Outlet Box is
ON
, is it safe to plug or unplug power whips to the Rack?
No, Whips should not be plugged until the Power source outlet Box is OFF
Yes, it's completely safe to plug and unplug a rack while power is on
22
When connecting Power Whips it is safe to...
None of the above
Wrap the power Whip cable around the busbar
Leave whips touching the ground
23
For any errors that happen in
ZConform
, the logs can be...
Both
Viewed on MES using the Z-Conform Log Viewer
Viewed locally on the unit
24
Should ONE person move a fully populated rack from one location to another by themselves?
No, Pulling a fully populated rack by yourself can result in injury
Yes, pulling a fully populated rack is fine
25
Any Servers that fail must have a
Defective System Traveler (Green ticket)
filled out.
False
True
26
What STEP occurs after a physical inspection, connecting power, network cables, and switch firmware/BIOS update?
Server-Level Test Check-in
Place Z-conform pass label on the Server
Notify a Champion
27
What WEB application system is for viewing data and reports from SFC?
Microsoft OneDrive
Manufacturing Execution System (MES)
OQT Log Viewer
28
What DESKTOP application is the system used to
collect
and
store manufacturing data
throughout the facilities?
Microsoft Teams
Shop Floor Control (SFC)
Manufacturing Execution System (MES)
29
A Switch may require updating the firmware and configuring the ports using...
Requirements are based on SKU type
Helpercommand (automated script tool using MES)
Manual update using PuTTY
Switch Update Config (Application on SFC)
30
If additional or incorrect network connections on a rack are present, it is likely a network loop can happen.
False
True
31
What Wifi connection in System Test do we use?
All of the above / Depends on Product
MFG-WIFI-AWS
MFG-WIFI-MSFT
MFG-WIFI-Verizon
32
What Tests are part of the
Burn-in Flow?
PXE boot
Assembly-Z, Updates, Pre-Z
CTCS, MdaSS, OQT
33
When REPLACING a
motherboard
, before checking the server out of repair what must be done?
Offline Scan
Assemble the server together first then Check-Out
Nothing, Repair Check-out
34
Before Replacing any component on a server what should you do?
Hot plug the server
Start a Seriel Session
Check the Repair History
35
When turning the power on and off
,
should a tech leverage themselves by holding onto the busbar?
NO, Holding onto the busbar can result in Electrical injury
YES, Hanging onto the busbar while flipping the power switches on is ok
36
NO Company data should be processed, stored, saved or sent to...
None of the Above
Personal e-mail, Cloud storage, or USB device
Co-workers ZT e-mail or Company Network Drive
37
What Applications can we use to Remote into a server?
PuTTY
All of the above
MobaXterm
MSFT gen6 Rack Assistant
38
Why is torque important?
It's not important, any torque can be used
None of the Above
The precise control of torque is key to quality assembly
39
When should you clock in to work at ZT?
On-time
30 mins before
No more than 20 minutes late
40
To see if multiple servers have passed a certain test, what application do you use on MES?
Test Flow
Product History
Product Status
41
You must always wear your ZT ID badge and have it visible as it is mandatory condition of employment
True
False
42
When working in System Test, hearing protection must be worn due to the
high decibel rating to prevent what?
Tinnitus
All of the above
Noise-induced hearing loss (NIHL)
43
Microsoft racks move like a shopping cart while Amazon racks the four wheels rotate independently.
True
False
44
To see the Pass status of an Amazon server running the ZT20 test, we can use
ZT20 Test Summary
on MES
True
False
45
What PPE (Personal Protection Equipment) is needed in System Test?
ESD Gloves
All of the above
ESD Foot/Wrist Straps
ESD jacket
46
Is it ok to log on and use a coworker’s laptop for any work-related reason?
False
True
47
When working on a Rack, pulling out
multiple
servers to work on and leaving them open is safe.
True
False
48
In case of a fire on a rack we should...
Alert others and management of fire, Refrain from touching the rack
Panic, Run out of System Test yelling fire
Stay in System Test and watch it burn
49
If a Server begins to fall off the rails you should...
Try and catch it, it's expensive
Call another tech over to help before it falls to the ground
Move out the way, a server falling on you can lead to injury or be fatal.
50
Which following practices are
prohibited
and create a security breach at all access points?
Letting Security know your reason for leaving the production floor.
None of the above
Tailgating and Piggybacking