stud
bud
Sign up
Log in
Home
Library
Explore
SAT
More
Central Sterile Study Guide 2020 Flashcards | StudBud
Explore
/
Central Sterile Study Guide 2020
Central Sterile Study Guide 2020
100 terms
·
StudBud Administration
·
170 plays
Imported from external platform
Flashcards
100 cards
F
Practice quiz
P
Host live
L
Questions
100
Answers
1
The relative humidity of the central service department should be:
Below 50%
Below 35%
Below 75%
Below 60%
2
Wicking materials are used to:
Allow air removal, steam penetration and facilitate drying
Cushion instruments from the extreme force in steam sterilizer chambers
hold water away from the bottom of the tray
dry instruments before sterilization
3
The term "intercosto" means
within the bladder
within the colon
between the ribs
between the toes
4
"Hyperglycemia" refers to:
high blood sugar
heart blockage
malignant tumor
tissue death
5
Which the following steps happens first when proceeding flexible endoscopes?
drying
manual cleaning
high level disinfection
leak testing
6
Patient care equipment should be stored in a________ condition
ready to inspect
ready to use
ready to clean
ready to sterilize
7
Behavior relating to what is “right and wrong” relative to the standards of conduct for you profession are called:
personal behavior
moral behavior
ethical behavior
legal behavior
8
Bowie dick tests should be run in:
Ethylene oxide sterilizers
Dynamic air removal steam sterilizers
Washers/sterilizers
Downward displacement sterilizers
9
Which of the following is NOT a reason for tracking supplies, equipment and instruments.
Measure item usage
Meet CDC and OSHA requirements
Ensure that items can be quickly located
Assist with quality processes
10
Parts of this surgical instrument?
Jaw, tips, box lock, shanks, handle, neck
Loop, handle, shank, blade
Rings, ratchet, shanks, box lock, jaw, tips
Proximal end, handle, tip serrations
11
Why is important to evenly distribute large instruments in a set?
follow instructions given by the supervisor
contact manufacturer
because the sterilizer has a big space
extra condensation will make instruments more difficult to dry
12
Blue stain on a scope, what is the reason?
sun drying
improper cleaning
wrong detergent
too much acidity in the water
13
Which of the following statements is correct?
Patient care equipment tracking requires a computer
Patient care equipment should only be tracked if it has excessive value
Tracking is only done if there is to be a charge to the patient
Tracking patient care equipment can prevent equipment shortages
14
Which of the following devices is used to reduce the risk of DVT's (Deep Vein Thrombosis)
sequential compression device
tourniquet
respirator
suction device
15
Which of the following information is NOT included in the MSDS?
inventory levels
product identification
special precautions
physical data
16
The FDA classifies sterilization packaging as a:
Class I
Class II
Class III
Class IV
17
Secondary containers of chemicals
Secondary containers of chemicals are not allowed in healthcare facilities
Must be labeled with a permanent marker
There are no restrictions for secondary container labels at this time
Must be labeled with a copy of the original manufacturer's label
18
Patient care equipment is typically stored:
in the biomed dept
sterile storage area of material management dept
central services dept
in the patient wards
19
Which of the following tells a primary meaning of a word?
combining vowel
root word
suffix
prefix
20
Which of the following is the most popular title for the central service department head?
director
coordinator
supervisor
manager
21
The term "hemi" is a
root word
combining word
prefix
suffix
22
Central Sterile Techs do not handle money, therefore ethics do not apply to them
True
False
23
In Central Service, the concept of "one-way flow of materials" refers to the movement of products:
From soiled to clean processing areas
From clean processing to soiled areas
From central service to surgical area
From surgical area to central service
24
"Lithotripsy" refers to:
visual examination of a joint
crushing a stone
removing an ovary
suction of fat tissue
25
When speaking, you should:
concentrate on the listener rather than oneself
be influenced by the listeners emotions
use technical jargon to impress the listener
concentrate on yourself rather than the listener
26
Dept. that perform CS functions may go by other names at different facilities. Example: Sterile Processing / Supply room
False
True
27
In a sterilization load containing 2 small basins, the chemicals indicators will be positioned.
in the lowest part
on the top
in the middle
on the handle
28
Technicians on the ____ department perform safety inspections and functional test on equipment
infection control
material management
facilities management
biomedical
29
In order to elevate the temperature in a steam sterilizer, you must:
Inject boiler amines
Achieve ambient pressure
increase steam pressure
decrease steam pressure
30
Ergonomic injuries:
Are risk factor for persons who perform repetitive or physical work
Happen only in the office setting
Are not a concern for central service employees
Are rare in today's work environment
31
Which of the following means "beside or near"?
pora
para
peri
parta
32
Soiled instruments and other items are received in the___ area of the Central Service Department.
packing
storage
sterile
decontamination
33
The system where items are ordered in large quantities to save money is called:
consignment
pick-n-pack
min/max
economy order quantity
34
Instrument washers sterilizers provide
flash sterilization process
a decontamination process
terminal sterilization
dry heat sterilization
35
What is the preferred pH of detergents used for most cleaning processes?
depends on water temperature
neutral pH
high pH
low pH
36
Which of the following statements is true?
We only communicate when we want too
message should contain all the possible information
words mean the same to everyone
none of the statements are true
37
Which of the following systems provides supplies and instruments for individual surgical procedures?
Exchange cart
Case cart
Requisition
Par level
38
Instrument sets & other required instrumentation needed for all surgical procedures for an entire day are usually pulled
2 days before the procedure
the day before the procedure
the morning of the procedure
immediately before the procedure
39
Which of the following is NOT an acceptable sterilization packaging material?
canvas
twill
barrier cloth
muslin
40
Both AORN and the joint commission recommend that
you get FDA approval for use
IUSS be used less frequently or not at all
only one sterilizer should be used for IUSS
only one tech should be allowed to operate the IUSS
41
In the future, which will more frequently become a requirement for working in a Central Service department
a formal education
experience
on the job training
reference from administration
42
When arranging plastic-paper pouches in the sterilizer, the pouches should be arranged:
paper to plastic
paper to paper
any way they will fit
plastic to plastic
43
Hands should have final rinse in what position?
fingers up
fingers down
it doesn't matter
hands sideways
44
Which of the following statements about endoscopes is true
flexible endoscopes are not easily damaged
not all endoscopes can be processed in the AER
ultrasonic cleaning is the process of choice
they can be steam sterilized
45
What is the coolest part of the sterilizer?
jacket
drain
gasket
door
46
The term "super-heated steam" means:
dry steam
steam that has had chemicals added to it
type of steam needed for high temperature sterilization
moist steam at sea level
47
Information regarding cleaning processes for endoscopes should be provided by:
operating room staff
APIC
SGNA
manufacturer of the instrument
48
The most efficient type of dry heat sterilizer is
mechanical convection sterilizer
special purpose dry heat sterilizer
dynamic air removal sterilizer
gravity convection sterilizer
49
The majority of medical terms are of either____ or____origin.
latin or english
latin or greek
french or latin
greek or french
50
Official inventory:
Can be counted as an asset on the facility's balance sheet
Does not exist in today's modern healthcare facilities
Is owned by the vendor but stored at the healthcare facility
Is owned by the healthcare facility but stored by the vendor
51
The root element, "gastro," refers to the:
liver
colon
stomach
leg
52
If an equipment malfunction causes harm to patients, it should be:
sequestered by OSHA personnel
returned to the biomed dept immediately
discarded immediately
sent to manufacturer for repair
53
Heat sensitive items:
should be disposable
should be thrown away
should not be immersed
cannot be steam sterilized
54
Disadvantages to a Case Cart Distribution System:
a waste of time
lag time between use and replenishment
Less efficiency organization
does not require orders
55
Material safety data are provided by:
Risk management
Manufacturer of the product
FDA
OSHA
56
The inventory system that uses two identical carts to facilitate supply replenishment is called the:
exchange cart system
Par level system
case cart system
requisition system
57
What is the concentration on an antiseptic liquid used in healthcare facilities?
20%-40%
60%-95%
70%-80%
200%-505%
58
The use of positive and negative air pressure in the Central Service Department is designed to take the place of heating
False
True
59
Package condensation will occur when:
because water leaked in the sterilizer
wet packs
placing hot packages on cold surfaces
door opened too soon
60
Which of the following is NOT a growing trend in Central Service?
The use of more reusable and more complex devices
Satellite-processing units with centralized management
de-centralization of central service department
Consolidation into entire integrated delivery networks
61
Which of the following surgical abbreviations might be used relating to a fracture bone?
LAVH
AKA
ORIF
CABG
62
Which of the following is NOT a feature of an instrument tracking system?
Financial data
Product updates and recall information
Productivity information
Quality assurance information
63
Since modern CS Departments are virtually risk-free, Central Service Technicians need not to be concerned with safety
True
False
64
All patient care equipment dispensed for use must be considered___& handled as such, regardless of its appearance
sterile
contaminated
dirty
clean
65
Preventive maintenance:
Is performed when a piece of equipment injures a patient
Is performed when a user unit notices a problem
Is designed to identify potential problems before they occur
Is done by central service equipment is dispensed
66
Implantable devices:
should be ran through an extended cycle
should be ran through the IUSS twice for proper processing
should be processed with EtO
should not be flash sterilized
67
Equipment should be inspected for obvious hazards such as cracked or frayed electrical cords:
Only when there are complaints from user department personnel
Whenever the equipment is cleaned
Only by trained biomedical engineering technicians
Only during preventive maintenance activities
68
Because all CS Departments have the same structure, healthcare facilities use one standardized job description
True
False
69
Test which use live bacterial spores to challenge the efficacy of the sterilization process
chemical indicator
ampulization test
chemical integrator test
biological indicator
70
The inventory system that stocks supplies by established levels is called:
case cart
exchange system
par level
ADT system
71
1005 ethylene oxide gas canisters should be stored:
in a chemical storage cabinet
In a chamber heated to 75 degrees
outside
in the refrigerator
72
The movement of supplies throughout the healthcare facility is called:
procurement
par-level system
distribution
case cart system
73
Central Sterile Techs must know approximately 100 instruments to be proficient at their jobs
True
False
74
Impregnated gauze strips may be sterilized using
dry heat sterilization
Steam sterilization
hydrogen peroxide gas plasma
EtO
75
Equipment leasing, and the rental differ in that:
Rental is usually done on a shorter-term basis than equipment lease
Leasing is for more expensive; Renting is for less expensive
Leasing involves purchase; rental does not require ownership
Leasing is an operating expense; equipment rental doesn't have cost issues
76
In this system items are owned by the vendor, but stores at the healthcare facility
min/max
just-in-time
in-house
consignment
77
The human resources tool that identifies major tasks performed by persons in specific positions is called a:
job specification
task summary
job description
job duties
78
The purpose of a combining vowel is to:
make it easier to spell
make it easier to pronounce
Tell the meaning of the word
tell the meaning of the root word
79
Career growth and progression is virtually non-existent for Central Service Technicians.
True
False
80
What is burning in a class C fire?
Wood or paper
Flammable liquid
Cloth or plastic
Energized electrical equipment
81
The__requires that the healthcare facility report malfunctions of medical devices to the FDA
FDA
OSHA
EPA
Safe Medical Devices Act
82
Which of the following tracking methods provides real time information?
Standard bar code
RFID
Laser etched bar codes
dot matrix application
83
Disposable components such as pads and tubing on patient care equipment should be:
be removed by biomed dept
be reprocessed for reuse
discarded at the point of use
be removed during maintenance
84
Which of the following is NOT required for sharps safety?
Never use your fingers to remove a blade form scalpel
Separate reusable sharps from other instruments when processing
Dispose of all single use sharps in an appropriate container
Wash all disposable sharps before discarding them
85
Which of the following is the most important factor necessary for team-work?
cooperation
attitude
promptness
loyalty
86
The amount of time that it takes to kill 90% of the microorganisms present on an object is called:
A D Value
exposure time
sterilization time
chemical value
87
Nosocomial infections are:
Most likely to occur on international travel
ones that occur while being treated in a hospital
resistant to antibiotics
Those without a cure
88
The term "hypo" means
quickly
above
below
measured
89
Sterilizer recording charts and/or printouts should be checked:
at the beginning and end of each shift
during and at the end of each load
at the beginning of the day
by the supervisor
90
Central Sterile Techs mus be able to adapt to change
True
False
91
Two most common temperatures used in steam sterilization are
350 and 320
300 and 350
320° AND 350°- 355° F
250° AND 270° - 275° F
92
Surgical instruments should be inspected:
after they are sterilized
during storage
before they are cleaned
after they are cleaned
93
A molecular reaction that created an uncontrolled release of energy is called:
Polymerization
Vapor density
Fire
Combustion
94
Which of the following questions is open- ended?
What problems do you frequently encounter on the job?
How long have you worked here?
What's your supervisors name?
Do you like your job?
95
Which of the following is not an example of communication?
Non –verbal expressions you use
The words you speak
ALL OF THE ABOVE ARE EXAMPLES OF COMMUNICATION
The words you write
96
Chemical indicators:
provide a visual that an item was exposed to sterilization perameters
prove an item is sterile
provides information that the spore inside the machine was killed
proves that the instrument was not damaged
97
Central Service workflow can be divided into 3 categories of items: soiled items, clean items and sterile items
True
False
98
Central service technicians who do not think they are being treated appropriately by their employer should:
discuss the situation with your supervisor
accept that that is just how things are
discuss the problem with your peers
find another job
99
A material that removes electrons from another substance is called:
a molecule
demagnetizer
oxidizing agent
an atom
100
Which of the following basic listening tactics is most useful?
None of the above tactics is useful listening tactics.
try to listen to specific facts
Focus on the delivery of the message rather than this content
Ignore all non-verbal communication “sent “by the speaker