4.1 module 3 Flashcards | StudBud
Explore
/
4.1 module 3
4.1 module 3
28 terms
·
StudBud Administration
·
92 plays
Imported from external platform
Flashcards
28 cards
F
Practice quiz
P
Host live
L
Questions
28
Answers
1
For residential & small commercial propane applications, system delivery for appliance inlet pressure typically _____
100 psig to 400 psig
10.5" to 14" w.c.
3.5" to 5" w.c.
2 psig to 10 psig
2
Natural gas meters are more widely used than propane meters.
True
False
3
210 CFH of natural gas =____ CFH of propane
2500
333.33
132
210
4
Effective , ____NFPA 58 prohibits the installation of single-stage regulators in residential central heating systems.
June 30, 2000
June 30, 1986
June 30, 1991
June 30, 1997
5
NFPA 58 States :The relief valve for a single-stage regulator may be the same as for a second-stage regulator.
False
True
6
When planning an installation, the meter must be plumb and level in all directions.
False
True
7
Natural gas has more btus per cubic foot than propane
True
False
8
Most propane appliances require an input pressure of around _____" w.c., or about ½ lb of pressure.
6
3.5
100
11
9
Vapor meters have ______ formed by a ____ diaphragm.
fixed-volume measurement compartments, one-sided
compound-volume measurement compartments, two-sided
fixed-volume measurement compartments, two-sided
multi-volume measurement compartments, two-sided
10
When sizing vapor meters for ½ lb systems, select the meter according to its capacity at 2" w.c. pressure drop.
True
False
11
The regulator should be constructed of materials that are compatible with LP-gas service and the external environment.
True
False
12
2nd stage regularos have a flow capacity to meet the total gas demand of all the appliances connected to the regulator.
True
False
13
When 2+are installed in the same location, NFPA 54 requires that each meter be tagged to indicate the specific customer.
False
True
14
Which of the following is
not
a factor to consider when selecting a regulator?
Manufacturer’s information
Customer preferences
Total gas demand
Pressure requirements
15
Btu/hr demand of the appliances will not affect the piping layout, size and number of gas piping entry points required.
False
True
16
To select the appropriate 2nd stage regulator, you will need to consider
All the above
Outlet pressure
Inlet pressure
Total gas demand
17
___________ are pre-assembled units designed to connect gas meters to supply piping.
Assembley Hangers
Meter bars
Pipe Blocks
Meter Connectors
18
_____ show the capacity of a regulator at different delivery pressures given the factory setting for outlet pressure.
Regulator Sizing chart
Delivery Pressure cake chart
Regulator performance curves
Linear Capacity chart
19
Do
not
adjust a regulator until you have been trained how to do so.
True
False
20
The delivery pressure of the first-stage regulators is set at the factory and is typically __________.
2 psig
10 psig
1000 psig
100 psig
21
Do
not
attempt to change the setting of a regulator relief valve.
True
False
22
Regulator selection is based on _______________.
downstream gas demand and regulator components
downstream gas demand and flow capacity
appliance operating pressure and regulator components
downstream gas demand and service technician requirements
23
To prevent regulator freeze-up due to vent blockage the regulator should be mounted so that the ___
diaphragm points upward
vent points downward
vent points upward
regulator points downward
24
Vapor meters are not affected by both the gas pressure inside the meter and the atmospheric pressure on the outside.
False
True
25
When reading the dials of a circular index, start with
furthest to the right and proceed left
anywhere, because it doesn’t matter
furthest to the left and proceed right
in the center and proceed outward
26
what is a factor to consider when designing a second-stage regulator system?
All The above
Appliance demand
Special requirements
Piping layout
27
Most propane vapor meters are designed to operate with an inlet pressure of ________
2 psig
11" water column
3.5" water column
100 psig
28
The inlet pressure for a
first-stage regulator
is determined by the
Appliance Demand
container pressure
Phases of the moon ( Tidal Force)_
Outlet pressure of the 2nd stage regulator