P(A-a)O2 Increases
>300 shunting
66-300 mmHg V/Q mismatch
On 100% A-a gradient 25-65 mmHg
2
Diagnose Carbon Monoxide Poisoning
: Uses a
Hemoximeter
Heavy Smokers 10-15%
Normal COHb: 1-3%
CO Poisoning>20%
Smokers 5-10%
3
Ventilation
summarized
Carbon dioxide from metabolism
EtCO2 measures exhaled CO2 at point of exit
change in ventilation within 10 seconds
4
can lead to a false sense of security in that pulse oximeter readings may appear normal although tissue hypoxia appear
cancer
anemia
5
Survivors (to discharge)
–Average ETCO2: ___
>30 mmHg
100 mmhg
6
Difference between alveolar and arterial PO2.
B and b gradient
A-a gradient
7
Mainstream
(hazards/complications)
Really only a concern in neonates and peds
deadspace and weight
8
Equipment Related Changers:
Increase ETCO2
Malfunctioning exhalation valve
Decreased minute ventilation settings
9
Signal Artifact ___
and some
causes are Low perfusion (hypotension, cold), motion artifact.
can cause errors in measurement.
may obscure the signal
10
ARDS standards
Mild: 200-300 (27% mortality)
Severe: <100 (45% mortality)
Moderate: 100-20 (32% mortality)
11
This is a capnograph of a 30-year old man who is under anesthesia. What does the slope at III indicate?
Airway obstruction
Cardiac arrest
12
Rationale for Noninvasive Monitoring
Continuous form of monitoring and tending
More comfortable for the patient
Less risk from infection or complications
13
What are the 4 types of hypoxia?
Hypoix hypoxia
Histotoxic hypoxia
circulatory hypoxia
Anemic hypoxia
14
P-to-F ratio <200 indicates
ARDS
OPT
15
ventilation occurs under conditions in which alveoli are
ventilated but not perfused.
PE, Hypovolemia, Cardiac arrest
Dead space
Shunt
16
refers to the dead space caused by
anatomical structures
(the airways leading to the alveoli).
Anatomic deadspace
Alveolar dead space
17
Patient Application - Sites in
Small children & babies
Finger, Toe, Ear lobe, Forehead
Wrist, Upper arm, Across foot, Toe
18
C(a-v)O2
= CaO2 − CvO2,
Normally, 4-5 vol%
measures temperature
measures the oxygen consumption of the tissues
19
CvO2=
Oxygen content of mixed venous blood
Normal CvO2: 120-16%
Normal CvO2: 12-16%
20
Each
g% Hb
can carry ___
99% of COD
1.34 mL of O2
21
Cor Pulmonale Recap:
Three major causes:
Obliteration of the pulmonary capillary bed
Polycythemia: increased red blood cell level
Increased vascular resistance.
22
Why do RT's compare the light absorption of Hb & HbO2 to measure the oxygen saturation of arterial blood?
Oxygenated/deoxygenated Hb absorb different amounts of light
to much light
23
Arterial-Venous Oxygen Content Difference:
Decreases:
Increased cardiac output
Peripheral shunting
•Cyanide, Hypothermia
Skeletal relaxation
24
Dead Space-Tidal Volume Ratio:
VD/VT =
Normal: 20% to 40%
PaCO2 – PetCO2 /PaCO2
25
Water Vapor can condense on the sensor cell & cause falsely high CO2 readings
Mainstream-disadvantages
open source
26
If the PetCO2 reading is low
immediately following intubation
- indicates tube is in the ___
esophagus
trachea
27
Hypoxemia may suggest tissue hypoxia, it
does not
necessary mean the absolute existence of tissue hypoxia.
True
False
28
If the mean airway pressure is 35 cmH2O and the patient is on 70% FiO2 with a PaO2 of 80
what is their OI?
98
31
29
Estimate of oxygen carried by hemoglobin & dissolved in blood plasma.
Normal Range = 17-20% volume
open system
Arterial Oxygen Content
30
70%, 80%, 90% equivalent to PO2 values of 40 mm Hg, 50 mm Hg, and 60 mm Hg. This rule works only in the middle range
where the curve is most linear
where its more
31
Grossly inaccurate
when a finger probe is placed on the ear or forehead
Monitor
Pulse Oximeter
32
NOT ACCURATE
when sat is > than70
Monitor
Pulse Oximeter
33
difference between abg and capnography
values of exhaled carbon dioxide
PaCO2-PetCO2 gradient
ventilation
34
Which of the following may have caused a patient to have a
sudden increase in PETCO2?
Bicarbonate administration
Pulmonary embolism
35
Abnormally
low arterial oxygen tension (PaO2)
and can be associated with hypoxia. Eg. can be offset by an increased CO
Hypoxemia
cancer
36
PaO2 reliable indicator
assuming that abnormal forms of hemoglobin & not present.
no age required
PaO2= 105- ¼ age in years
37
Decrease in EtCO2
Hypothermia
Increased PaCO2, sedation, sleep, cooling
Increased minute ventilation
Decreasedmuscular activity (muscle relaxants)
38
RBC production is called
erythropoiesis
Increased RBC’s is called
hypoment
polycythemia
39
Cor Pulmonale:
condition commonly arises out of complications from high blood pressure in the pulmonary arteries, occurs
Leads to right ventricular failure
Increased right ventricular work
Pulmonary arterial hypertension
40
refers to
external artificial airways and circuits
that may, add to the total dead space during mechanical ventilation.
Mechanical dead space
open space
41
Increases in EtCO2
Increased cardiac output (during resuscitation)
Malignant hyperthermia
Increased muscular activity (shivering)
42
ETCO2
is usually ___ lower than
PaCO2
500-1087 mmHg
5-10 mmHg
43
What are
norms for shunting
?
3-5% is Normal
20-30% Life threatening
10-20% tolerable
44
P-to-F ratio 200-300 indicates
cancer
acute lung injury
45
low or inadequate oxygen
for
aerobic cellular metabolism.
Absence of O2, lactic acid is produced causing acidosis
Hypoxia
tachycardia
46
perfusion occurs under conditions in which alveoli are
perfused but not ventilated.
Ex: Mucus plugging, Atelectasis
Shunt
Dead space
47
Pulse Oximeter maintenance:
Wipe probe & monitor with an
alcohol soaked cloth
between patients.
False
True
48
___ of Oxygen will dissolve in every
100 mL of blood for every 1 mmHg of PO2
99ml
0.003 mL
49
refers to ventilated areas that are
designed for gas exchange (alveoli)
, but do not actually participate.
Alveolar dead space
Anatomic deadspace
50
What is one problem associated with using mainstream sensors in capnometry?
Accumulation of moisture,secretions, and debris
dryness
51
The oxygen saturation result from the blood gas analyzer is
calculated NOT measured!
True
False
52
Normal: 5-10 mmHg
on room air
, should not exceed 30mmHg. Normal=
25-65 torr
on 100%
A-a gradient
B and b gradient
53
P-to-F ratio:
Normal=
900 or more
380 or greater
54
Non-survivors
–Average ETCO2: ___
4-10 mmHg
100 mmhg
55
___ the measurement of the amount of light that is absorbed as it passes through a substance.
Spectrophotometry
visual cues
56
Total Oxygen Delivery
DO2 = QT × (CaO2 × 10)
Normally, about 1000 mL/min
Normally, about 89000 mL/min
57
In healthy person:
98% of the oxygen
that ___ into pulmonary capillary
combines with Hemoglobin
uptakes
diffuses
58
During CPR the PetCO2 should ____!!
fall apart
increase
59
hormones respond by
stimulating bone marrow to increase red blood cell (RBC)
production
cancer
Chronic hypoxia
60
Cor Pulmonale
leads to:
accumulatio of to much water
Accumulation of venous in large veins
61
Reflects changes in Oxygenation
within 5 MINUTES
Monitor
Pulse Oximeter
62
On 100%
A-a gradient
>300 shunting
25-65mmHg
66-300 mmHg V/Q mismatch
63
Sudden Loss of Waveform:
Fully obstructed Airway,..
Airway dislodge
Ventilator circuit disconnect or systemleak
64
A decrease in ETCO2
would indicate a _____ in
ventilation or a decrease in perfusion
.
ex: dead space disease, pulmonary embolism, hypovolemia
decrease
increase
65
Affinity to hemoglobin
is greater than
less than oxygen
200 X that of oxygen
66
Equipment Related Changers:
Decrease in EtCO2
Circuit leak or partial obstruction
Poor sampling technique
Increased minute ventilation settings
67
Verification of airway placement:
False readings can occur in patients who have ben without CPR for a period of time.
Yellow=Normal
Purple=POOR
68
__are simple bedside devices that measure Hb saturation by way of a noninvasive probe
needles
Pulse oximeters
69
Arterial-Venous Oxygen Content Difference:
Increases
Decreased cardiac output
Hyperthermia
Seizures
Exercise
70
An
increase in ETCO2
would indicate a ____ in
ventilation
increase
decrease
71
Normal is 5-10 mmHg
, Difference greater than
15 mmHg indicates a pulmonary embolism
ventilation
PaCO2-PetCO2 gradient (Written as P(a-e)CO2)
72
Four things
to verify
prior
to reporting results:
Waveform
heart rate
signal strength
Clinical Correlation
73
Patient Application - Sites in
Adults & children
Finger, Toe, Ear lobe, Forehead
Wrist, Upper arm, Across foot, Toe
74
The weight measurement of hemoglobin, in reference to
100 mL of blood
, is known as the
liters per miles
grams percent hemoglobin (g% Hb)
75
Secretions can block sample tubing, Water trap required
mechanical vents
sidestream disadvantages
76
A
Safety Monitor must be:
no false goodness
always detect danger
77
A
pulse oximeter
sensor is
made up of two different parts:
An light emitting diode
A photodetector
78
Normal Capnogram
1. Gas from apparatus dead space/proximal conducting airways
2. CO2 emptying from proximal alveoli & CENTRAL airways
3. ALVEOLAR GAS
79
Pulse oximetry
is based on which process?
oxygen
Spectrophotometry
80
Cor Pulmonale Recap:
The term used to denote:
Pulmonary arterial hypertension
Increased right ventricular work
Right hypertrophy
Right ventricular failure
81
Mainstream-
DISAVANTAGES:
Secretions and humidity can block sensor
many complications
82
Increased values indicate the patient’s condition is worsening and Normal is
less than 10. (Paw* FiO2)/ PaO2) *100
Oxygen Index
Oxygen pulse
83
Oxygenation
summarized:
Oxygen for metabolism
SpO2 measures % of O2 in RBC
Reflects change in oxygenation within 5 minutes
84
Cor Pulmonale
caused by three main manifestations seen in chronic pulmonary disease
Increased Pulmonary resistance from the vasoconstriction
Destruction of pulmonary vascular bed
Increased viscosity of blood from polycythemia
85
The
Masimo RAD-57 is the world’s first and only
PulseCO-Oximeter
HR monitor
86
Measures exhaled carbon dioxide content
and plots it against time using infrared absorption
CAPNOGRAPHY
albuterol
87
Under conditions of low blood flow, which location may give a more accurate pulse oximetry reading than a finger tip?
nose
ear
88
Capnography in Bronchospastic Diseases:
If lack of alveolar plateau consider:
Insufficient alveolar ventilation, COPD
partial obstruction of upper airway
tube partially occluded