Image Production II Flashcards | StudBud
Explore
/
Image Production II
Image Production II
206 terms
·
StudBud Administration
·
93 plays
#radiography #imageproduction #digitalimaging #digitalradiography #pacs
Flashcards
206 cards
F
Practice quiz
P
Host live
L
Questions
206
Answers
1
Gadolinium oxysulphide material is made from small crystals in an unstructured or ______ layer
turbid
composite
photodiode
turbine
2
Following are all techniques to reduce possibility of image lag, except:
Increase amount of time btwn exposures
Set appropriate technical factors
Wait the appropriate 60 minutes before using the same plate
Reduce unattenuated beam by increasing collimation
3
With PSP and FPD, radiographic contrast is controlled by what?
LUT (look up table)
mA (milliamperage)
kVp (kilovolt peak)
mAs (milliamperage per sec)
4
Thinner plates result in ______ image sharpness bc of reduced amount of light spreading.
even
lesser
greater
unchanged
5
Type of motion that will blur the grid lines and eliminate interferance
oscillating
criss cross
bouncing
pendulum
6
If an image has a bit depth of 8, how many shades of gray are in the image?
16
256
2
50
7
Used to review images after acquisitions but before sending them to the radiologist.
tech quality control stations
diagnostic main computer
physician review station
technologist viewing stations
8
Digital images are recorded as multiple _________ and divided into array of small elements.
layers
colors
image sequences
numeric values
9
Initial digital image appears linear when graphed bc all gray shades are visible, resulting in:
high resolution
wide latitude
low resolution
narrow latitude
10
T or F: The first
T
hin
F
ilm
T
ransistors were made of amorphous silicon and amorphous selenium
false
true
11
One of the first uses of digital imaging was in...
1960's
1990's
1980's
1970's
12
Should be monitored from modality to PACS & from archive to workstation
workstation speed
data speed
image transfer speed
13
T or F: background signal is unimportant therefore imaging plates don't need to be erased
True
False
14
Range of exposure diagnostic image values the image detector is able to produce.
Detail
Scale of contrast
Latitude
Resolution
15
Amount of detail present in any image is known as it's:
spatial resolution
positioning latitude
noise quality
contrast resolution
16
Storage phosphor plates are similar to...
buckies
digital flashpads
intensifying screens
film
17
The internet is based on what kind of network topology?
mesh topology
bus topology
ring topology
star topology
18
In digital x-ray, mAs has more influence on _______ than on density.
penetration
subject contrast
image noise
detail
19
More pixels = _______ image resolution
greater
less
20
Imagers that use heat to process latent image that is etched into the silver emulsion by laser
dry imager
chemical imager
heat imager
wet imager
21
Each pixel contains pieces of information called _______.
Pix
Byte
Point
Bit
22
Surpressing frequencies, also known as ________ can result in loss of small details.
masking
edging
processing
ghosting
23
T or F: biggest advantage of CCD relates to demagnification issues and reduced DQE
False
True
24
In PSP, the light is picked up by one of these two things then converted to an electric signal?
photomultiplier tube
flashpad
CCD array
FPD
25
In direct conv., each pixel contains a ____ that absorbs electrons & generates electric charges
cat
photomultiplier
photodiode
scintillator
26
Common measurements functions include all of the following except:
angle measurement
extremity measurement
region of interest
distance measurement
27
How long does it take between exposures for the plate to erase the old image?
60 minutes
2 minutes
3-5 seconds
25 seconds
28
T or F: matrix size change will affect FOV, but FOV or matrix change won't affects pixel size.
True
False
29
The ________, or microprocessor, is a small chip found on the mother board.
Central processing unit (CPU)
CMOS
microchip
network card
30
Which of the following is not a major OS in use today?
Dell Hardware
Microsoft Windows
Macintosh OS
Unix/Linux
31
Any computer that a health care worker uses to view a digital image
display workstation
archive server station
PACS processing screen
LCD monitor
32
T or F: the two types of film digitizers are laser digitizers and CCD digitizers
False
True
33
Image management station is also known as:
qc workstation
file room workstation
navigation station
physician workstation
34
Software that controls computer hardware & acts as a bridge btwn applications & hardware
operating system (OS)
central processing unit
server based network
CRT monitor
35
In indirect conversion, signals are first converted to _______ and then to an electrical signal
light
sound
photo
phosphor
36
Type of OS used to control specific machinery, such as digital x-ray consoles
real time
multiuser
single user, single task
single user, multi task
37
Moving images via telephone lines to & from remote locations is referred to as...
teleradiography
teletomography
phonoradiography
CR radiography
38
If image is taken prior to detector releasing signal from previous image, what can happen?
faint image of previous exposure (image lag)
the new image erases the old image
two separate images will show on the screen
39
Series of connections, controllers, & chips that creates information highway of the computer
ports
highways
buses
CPU
40
Relationship between the height of the lead strips and the space between the lead strips
grid focus
grid cleanup factor
grid ratio
grid frequency
41
Direct capture uses __________ as an x-ray absorber.
pixel matrix
scintillator
intensifying screens
photoconductor
42
Ability of imaging system to demonstrate small details of an object.
Look up table
Contrast resolution
Primary detail
Spatial resolution
43
Allows tech to match image information with patient information.
ascession number
MRN number
PACS
barcode label
44
Cheapest form of storage:
DVD
Blue-ray
CD
USB
45
In general projection radiography PSP imaging, resolution is approximately:
3-5 lp/mm
1-2 lp/mm
1.5-3.5 lp/mm
2.55-5 lp/mm
46
Uncommonly, malfunctions in the detector can cause:
image artifacts
channeling
noise
nothing
47
RAID stands for:
redundant array of independent disks
redundant array of imaging documents
relocation aquisition of inexpensive disks
48
Smallest element in a digital image, also known as picture element.
pixel
bit
matrix
byte
49
True or False: PSP systems are less sensitive to low levels of radiation.
False
True
50
Network with multiple pathways interconnecting devices and networks
mesh topology
star topology
bus topology
ring topology
51
MRI was introduced in what decade?
2000's
1960's
1980's
1990's
52
True or False? PACS provides image access to multiple users at the same time.
True
Blue
False
Red
53
TJC (formerly JCAHO) accreditiation necessary for all the following except:
malpractice insurance
reimbursements from insurance companies
funding for new equipment
medicaid funding
54
Indirect conversion detectors are similar to direct because they use _________
TFT technology
CCD arrays
on and off switches
55
PSP reader that has optical stage, scanning laser beam, photomuliplier, & ADC converter.
direct scan
round scan
point scan
line scan
56
ADC stands for...
Automatic to Direct Converter
Automatic Divergence Conversion
Analog to Digital Converter
Analog to Digital Charge
57
Type of radiography that uses film & intensifying screens in it's image formation process
Original Radiography
CR Radiography
Conventional Radiography
DR Radiography
58
A cassette's phosphor layer is also known as it's
light shielding layer
conductive layer
active layer
support layer
59
How efficiently a system converts x-ray input signal into a useful image.
Detective Quavo Element
Detail Quadratic Equation
Deficient Quantum Element
Detective Quantum Efficiency
60
CMOS was developed by what company?
MAGA
USDA
FDA
NASA
61
When images are produced with uniform density and contrast, regardless of exposure amount.
nyquist theorem
automatic rescaling
contrast regulation
sampling
62
On the LUT, _________ is increased and decreased by moving the line up or down the y-axis.
spatial resolution
noise
brightness (density)
visible contrast
63
Important phase in establishing parameters that determine collimation & histogram function
image recognition phase
collimation angle phase
data phase
post processing elemental phase
64
Window level represents
detail
shades of gray
quality
brightness
65
Image acquisition, display workstations, & archive servers are 3 fundamental parts of:
RIS
PACS
HL-7
DICOM
66
DICOM stands for Digital Imaging Communication ____________________
in marketing
in modalities
in medicine
67
Changes to images before PACS reduces the amount of manipulation the ________ can do.
nurse
PACS admin
radiologist
other technologist
68
On most digital systems, kVp values range from:
30-130
55-110
70-120
45-120
69
Plan for the systematic observation & assessment of diff. aspects to make sure standards met
quality control
quality assurance
70
Post processing is performed by who?
Radiologist
Supervisor
Technologist
QA Employee
71
Amount of exposure received by the image receptor.
scatter absorption
penetration
exposure index
detail
72
Early PACs systems were developed by...
NASA
US Military
Insurance Companies
Homeland Security
73
Moire effect happens because the grid lines and the scanning laser are:
parallel
level with eachother
on top of one another
perpendicular
74
More light spread will result in ________ MTF.
lower
equal
higher
bad
75
Modulation transfer function (MTF) is the ability of the system to record available __________.
shades of gray
spatial frequencies
light
noise variances
76
Aliasing (also called foldover/biasing) causes mirroring of the signal at _____ the frequency.
half
1/2
1/4
double
77
Indirect capture is similar to PSP because x-ray energy stimulates a.....
thin film transistor
scintillator
conversion tube
photomultiplier
78
Process where x-ray energy is converted directly into an electrical signal.
Moire effect
Direct capture
Field of view
Indirect capture
79
Typical grid frequency is between ____ and _____ lines per inch
52 and 180
80 and 152
110 and 180
10 and 50
80
T or F: a field effect transistor or silocon TFT reacts like a switch (in direct conversion)
False
True
81
The ability of a digital system to display subtle changes in the shade of gray.
Spatial resolution
Latitude
Detail
Contrast resolution
82
Converting digital input data to an image w/appropriate brightness & contrast is referred to as
contrast manipulation
processing
spatial frequency
brightness adjustment
83
Ultimate focus in health care is:
have the quickest times possible while getting a good review
improvate patient care & provide high quality service
84
PSP plates record a _______ range of exposures, so only the optimal density range is processed.
wide
rough
small
random
85
When insufficient light is produced, image is grainy, a condition known as
quantum mottle/noise
insufficient detail
artifacts
motion
86
In conventional x-ray, optical density is primarily controlled by what?
kVp
LUT
brightness
mAs
87
Movement of the image plate through the reader.
raster scanning
fast scan direction
slow scan direction
scan system
88
Reduction of the area of the beam that reaches the patient through the use of lead shutters
magnification
cropping
focal spot size
collimation
89
In digital x-ray, images will appear on the monitor in what amount of time?
2-3 seconds
3-5 seconds
2 seconds
4 seconds
90
Refers to the number of grid lines per centimeter or lines per inch
line pattern
grid frequency
grid focus
grid ratio
91
System in which images are sent directly to archive server after acquisition
PACS workflow
client/server based system
network based system
Quality control
92
DICOM is standards that allows PACS and __________ to communicate in the same language.
networks
patients and families
other hospitals' PACS
imaging modalities
93
Amount of electrons produced relative to the incident light from the scintillator
quantum mottle
DQE
quantum efficiency
noise control
94
Noise that occurs when some pixels in the chip don't work at all, common in digital
amplification noise
white noise
statistical noise
dark noise
95
In conventional radiography, contrast is primarily controlled by what?
field size
lookup table
kVp
mAs
96
Network in which the devices are connected in a circle.
bus topology
star topology
ring topology
97
True or false: facilities prefer when the tech manipulates images before sending them to PACS
True
False
98
Gadolinium oxysulphide is considered to be a(n):
structured phosphor
unstructured phosphor
99
Window width represents
detail
shades of gray
brightness
quality
100
On the LUT, contrast can be increased or decreased by changing what?
the slope
bringing the line up
the first number
the left side
101
Number of bits within a pixel is known as?
matrix size
pixel area
bytes
bit depth
102
In direct conversion, more than __________ pixels can be read & converted to image in 1 second
one million
ten thousand
two billion
three hundred
103
Any undesirable densities on the processed image other than those caused by scatter or fog
low contrast
noise
low mAs
artifacts
104
A device/system that captures or measures a continuously changing signal.
analog
CCD
photostimulator
digital
105
The first commercial CT scanners imaged only the...
head
chest
abdomen
spine
106
On a histogram, values on the left represent ______ areas.
light
medium
dark
unexposed
107
The two ways to measure detector performance (select two):
recording dead pixels on each live patient
observation of low-contrast objects in a phantom
performing exams on cadavers to get real time numbers
numerical measurement of spatial resolution & DQE
108
QC technologists perform testing how often
daily
monthly
weekly
annually
109
T or F: image is digitized by both position (spatial location) and intensity (gray level)
False
True
110
PACS can accept any image that is in ________ format.
Digital
Compressed
Analog
DICOM
111
Traditionally kVp was chosen for _________.
quantity
contrast
penetration
brightness
112
Scans the analog film and produces numeric signals for each part of the scanned film
phosphor plate reader
scintillator
image producer
film digitizer
113
Reading of pixel values could be off because of all of the following, except:
unexpected body part in image
gonadal shielding or prosthesis in image
motion of patient
system fails to recognize collimated border
114
Indirect conversion uses a phosphor such as ___________ to absorb x-rays and produce light
gadolnium formaldehyde
barium fluorohalide
barium sulfate
gadolinium oxysulphide
115
Most storage phosphor plates are made of what?
lead strips
barium fluorohalide
barium formaldehyde
halide flurobromine
116
Line scan readers use a ________ linear array photodetector.
charged coupled device (CCD)
FPD
transformer
ADC
117
Who can fix broken latches or hinges?
service personnel
radiation safety officer
technologist
QC technologist
118
This digital acquisition modality uses storage phosphor plates to produce projection images.
DR
PACS
PSP
CMOS
119
This layer of the cassette sends the light in a forward direction.
conductive layer
phosphor layer
reflective layer
protective layer
120
The ability to respond to varying levels of exposure that allows seeing more tissue densities
noise
dynamic range
spatial resolution
kVp penetration
121
Cracks in the plate appearing as radioluscency on the image are known as
image processing artifacts
imaging plate artifacts
plate reader artifacts
122
Functions primarily used radiologist to increase size of an image area are all of these except:
zoom
magnify
pan
crop
123
Who will need to clean or replace the light guide on a damaged plate reader?
technologist
QC technologist
service personnel
radiation safety officer
124
Network that spans large area, used to connect computers that aren't physically attached
local area network
wide area network
peer area network
server based network
125
This layer traps electrons during exposure, commonly made of barium fluorohalide.
reflective layer
backing layer
conductive layer
phosphor layer
126
Constant measure to be monitored is to make sure all images make it to ______.
DICOM
RIS
PACS
HIS
127
In indirect capture, this gives off light that is detected and turned into an electric signal.
scintillator
film
laser beam
electrons
128
Number of gray tones a pixel can produce is _____ to the power of the bit depth.
zero
8
2
256
129
Similar to a hub but sends data only to those devices in which the data are directed.
network switch
network router
network bridge
130
True or False: In client/server based systems, any exam sent to PACS is available anywhere
False
True
131
Adding a black background around the original collimation edges, this is known as:
bordering
blackening
shuttering
post processing
132
Network w/centralized computer that controls operations, files, and sometimes programs
server based network
component network
peer to peer network
133
Cassettes contain ______ to protect against static electricity, dust and mechanical damage.
lead strips
protective housing
plastic backing
anti-static material
134
Early CT machines took a few ________ to reconstruct raw data into a recognizable image.
days
minutes
hours
weeks
135
In conventional x-ray, exposure latitude is based on....
the thickness of the cassette
how large or small the film is
the characteristic response of the film
how old the piece of film is
136
T or F: RIS holds patient's full medical info, HIS holds all radiology specific data
True
False
137
T or F: two types of scinitillation layers are structured and unstructured
False
True
138
True or False: Digital images are formed through multiple samplings of a signal.
True
False
139
What are the two types of PSP readers?
indirect & direct scan
direct scan & point scan
line scan & round scan
line scan & point scan
140
Process where x-rays are absorbed, converted to light which is converted to an electric signal
Indirect Capture
Moire effect
Direct Capture
Grid cleanup
141
In direct capture, energy is detected by a ________ that converts it into an electric signal.
conductive belt
photoconductor
photophosphor
look up table
142
When do you erase cassettes if you are unsure of the last erasure?
after 48 hours
Before use
after 24 hours
143
Small area networked w/series of cables or wireless access points; devices on same network
wide area network
local area network
hospital network
peer to peer network
144
Each pixel or ____ contains 3 electrodes that hold the electrons in an electric potential well.
detector element (del)
detective quantum element (dqe)
charged coupled device (ccd)
thin film transistor (tft)
145
When signal is reproduced, frequencies above the Nyquist frequency will cause:
nyquist theory
aliasing
noise
rescaling
146
Two or more objects sharing resources/info; devices interconnected by communication channels
hospital information system
bus
network (including LAN and WAN)
network hub
147
Function that allows the QC tech to select one or more local computers to recieve images.
manual send
location preferencing
direct messaging
manual reciept
148
Noise created by the lack of light photons from the scintillator
amplification noise
white noise
statistical noise
dark noise
149
White lines parallel to the direction of plate travel caused by dust or scratches are known as
plate reader artifacts
imaging plate artifacts
image processing artifacts
150
A place where records or documents are preserved
archive
hard drive
HIS
RIS
151
Edge enhancement is also known as
window leveling
low pass filtering
shuttering
high pass filtering
152
A perfect system would have an MTF of ______?
1 or 100%
100
10 or 100%
0
153
Short term memory storage for open programs
netowrk card
Random allocating memory
WAN
Random access memory
154
In digital x-ray, density is controlled by what?
image processing algorithms
noise
mAs
LUT
155
High resolution image plates contain a _______ phosphor layer compared to the standard plates.
longer
thicker
thinner
shorter
156
Organization that sets standards that are used in most health care applications, btwn HIS & RIS
HL-7
PACS
HIS
DICOM
157
A networked group of computers, servers, and archives used to manage digital images.
Archive
PACS
WAN
Network system
158
A line of TFT switches allows electrical charge info to discharge when switches are _______.
Open
Closed
159
Used to blacken out the white collimation borders, effectively eliminating veil glare.
automatic shuttering
cropping
filtering
blackening
160
An appropriate grid for portables is 6:1, where as an appropriate grid for the department is:
10:1
8:1
4:1
12:1
161
How many people at one time can open a study on client/server based systems?
One
Only two - tech and radiologist
Multiple
162
Simplest device that can be used to connect several pieces of equipment together
network switch
network hub
interface card
network medium
163
Plate is scanned, image location & then signal size determined, & value is placed on each pixel
Image Sampling
ADC conversion
Histogram Production
PSP reading
164
Most popular type of amorphous silicon detecter uses a ______ scintillator.
phosphor
Gd2O2s
CDL
Csl
165
Which is not a following type of noise associated with CCD technology
amplification noise
dark noise
white noise
statistical noise
166
Anything that interferes with the formation of the image.
Noise
Loudness
Artifacts
Motion
167
Universally accepted standard for exchanging medical images
PACS
WAN
DICOM
168
Acquisition modalities send images to designated reading stations in what type of system?
network systems
client/based systems
distributed systems
CT systems
169
Used to move through images, series, studies, and patients
image storage
post processing functions
navigation functions
web based systems
170
In indirect conversion, the phosphor layer is also known as the ________ layer
absorption
light reflective
translation
scintillation
171
CT units took several ________ to acquire a single slice of information
seconds
minutes
days
hours
172
Movement of the laser across the imaging plate.
raster scanning
fast pace reading
fast scan direction
slow scan direction
173
Who introduced the CT scanner?
Godfrey Hounsfield
Thomas Edison
William Roentgen
Clarence Daly
174
Referred to as the image's appearance on the display monitor of the computer.
Window level/window width
Contrast scale
Gray tones
Brightness
175
Which is most inexpensive, easier to repair, and more simple? TFT or CCD
CCD
TFT
176
Imagers that use chemicals to process film that has been exposed to the laser
chemical imagers
dry imagers
digitizing imagers
wet imagers
177
Will changes in the field of view affect the size of the pixel matrix?
No
Not sure
Yes
Sometimes
178
Noise occurs when the CCD chip operates w/o radiation stimulation
amplification noise
white noise
dark noise
statistical noise
179
T or F: info can never be misrepresented or lost even if there's defects in operation of device
True
False
180
T or F: 3 types of compression are lossless, lossy, and no compression
true
false
181
In client/based servers, archive server is handling many requests at once and can become:
bottlenecked
crashed
frozen
repetitive
182
Maps the image grayscale values into visible output intensity on a monitor or printed film.
Look up table
Scintillator
Window level
ADC
183
Comprehensive set of activities designed to monitor & maintain systems that produce a product
quality assurance
quality control
184
Film is inside a cassette that contains an intensifying screen in ________ radiography?
computed
diagnostic
digital
conventional
185
May be used to look up exams for a physician or print copies of images for the patient
PACS network
image management stations
QC station
186
Many PACS reading stations also have what capability?
radiologist duties
image e-mailing
image processing
diagnosing
187
These systems use an x-ray absorber material coupled to a TFT or CCD to form images.
Grid factors
Matrix systems
Flat panel detector (FPD)
Photostimulable phosphor (PSP)
188
Data within a collimated area produces a graphic representation of optical densities called a?
image history
salpingogram
histogram
level scale
189
Slow scan (image plate through the reader) is also known as
transisting
raster scan
translation
amplification
190
Occurs when fewer pixels in the nieghborhood are included in the signal average.
collimation cutoff
edge enhancement
image aliasing
image manipulation
191
Network which all devices are physically attached to & listen for communication on single wire
star topology
bus
bus topology
ring topology
192
Considered to be the second major milestone in medical imaging
Computed Tomography
Radiography
Magnetic Resonance Imaging
Sonography
193
Cassettes are backed by a thin sheet of aluminum that absorbs what?
backscatter radiation
useful beam
primary radiation
extra photons
194
True or False: Quality can be considered a service or a product.
true
false
195
RAM takes data from the _______ so it can handle processing needs of running programs
hard drive
computed discs
CPU
buses
196
Reject analysis is performed how often
daily
monthly
annually
weekly
197
Early PACS systems moved images from __________ to established hospitals.
clinics
battlefields
naval ships
foreign countries
198
Systems that are a simply light proof container that protects image plate from light & handling
Cassette based PSP
Film screen
Digital radiography
199
Stationary grid can interfere with image and produce lines, known as the:
nyquist effect
grid line factor
moire pattern
zebra phenomenon
200
X-ray photons are absorbed by coating material & immediately converted into electrical signal
indirect conversion
direct conversion
201
Grid lines will be finer/less interfering when the grid frequency is:
an even number
lower
spread out
higher
202
In PSP systems, a _____________ scanned over the plate releases the latent image.
fluroescent beam
heated beam
focused LED bulb
focused laser light
203
Which phosphor produces more lightspread/decreases efficiency when stimulated?
structured
unstructured
204
True or false: changes in the matrix size will not affect pixel size.
False
True
205
CCD is only included in what process(es)?
1 & 2
Neither
Direct capture
Indirect capture
206
T or F: In client/based systems, if the archive goes down, the entire system is still operable.
True
False