stud
bud
Sign up
Log in
Home
Library
Explore
SAT
More
4.1 module 3 Flashcards | StudBud
Explore
/
4.1 module 3
4.1 module 3
27 terms
·
StudBud Administration
·
82 plays
Imported from external platform
Flashcards
27 cards
F
Practice quiz
P
Host live
L
Questions
27
Answers
1
Do
not
adjust a regulator until you have been trained how to do so.
False
True
2
Do
not
attempt to change the setting of a regulator relief valve.
True
False
3
Effective , ____NFPA 58 prohibits the installation of single-stage regulators in residential central heating systems.
June 30, 1991
June 30, 1986
June 30, 2000
June 30, 1997
4
Which of the following is
not
a factor to consider when selecting a regulator?
Pressure requirements
Manufacturer’s information
Customer preferences
Total gas demand
5
Vapor meters are not affected by both the gas pressure inside the meter and the atmospheric pressure on the outside.
True
False
6
Natural gas has more btus per cubic foot than propane
False
True
7
Btu/hr demand of the appliances will not affect the piping layout, size and number of gas piping entry points required.
False
True
8
The delivery pressure of the first-stage regulators is set at the factory and is typically __________.
100 psig
10 psig
2 psig
1000 psig
9
2nd stage regularos have a flow capacity to meet the total gas demand of all the appliances connected to the regulator.
False
True
10
When 2+are installed in the same location, NFPA 54 requires that each meter be tagged to indicate the specific customer.
False
True
11
Most propane appliances require an input pressure of around _____" w.c., or about ½ lb of pressure.
100
11
6
3.5
12
Most propane vapor meters are designed to operate with an inlet pressure of ________
3.5" water column
11" water column
2 psig
100 psig
13
For residential & small commercial propane applications, system delivery for appliance inlet pressure typically _____
100 psig to 400 psig
10.5" to 14" w.c.
2 psig to 10 psig
3.5" to 5" w.c.
14
Vapor meters have ______ formed by a ____ diaphragm.
fixed-volume measurement compartments, two-sided
multi-volume measurement compartments, two-sided
fixed-volume measurement compartments, one-sided
compound-volume measurement compartments, two-sided
15
When planning an installation, the meter must be plumb and level in all directions.
True
False
16
The regulator should be constructed of materials that are compatible with LP-gas service and the external environment.
True
False
17
what is a factor to consider when designing a second-stage regulator system?
All The above
Piping layout
Special requirements
Appliance demand
18
To select the appropriate 2nd stage regulator, you will need to consider
Total gas demand
Inlet pressure
Outlet pressure
All the above
19
___________ are pre-assembled units designed to connect gas meters to supply piping.
Meter Connectors
Assembley Hangers
Pipe Blocks
Meter bars
20
NFPA 58 States :The relief valve for a single-stage regulator may be the same as for a second-stage regulator.
False
True
21
To prevent regulator freeze-up due to vent blockage the regulator should be mounted so that the ___
vent points downward
regulator points downward
diaphragm points upward
vent points upward
22
Natural gas meters are more widely used than propane meters.
False
True
23
Regulator selection is based on _______________.
downstream gas demand and flow capacity
downstream gas demand and service technician requirements
downstream gas demand and regulator components
appliance operating pressure and regulator components
24
The inlet pressure for a
first-stage regulator
is determined by the
Outlet pressure of the 2nd stage regulator
Phases of the moon ( Tidal Force)_
Appliance Demand
container pressure
25
_____ show the capacity of a regulator at different delivery pressures given the factory setting for outlet pressure.
Regulator Sizing chart
Regulator performance curves
Linear Capacity chart
Delivery Pressure cake chart
26
When sizing vapor meters for ½ lb systems, select the meter according to its capacity at 2" w.c. pressure drop.
False
True
27
When reading the dials of a circular index, start with
furthest to the right and proceed left
furthest to the left and proceed right
anywhere, because it doesn’t matter
in the center and proceed outward