13 & 14 Ultrasound Physics Flashcards | StudBud
Explore
/
13 & 14 Ultrasound Physics
13 & 14 Ultrasound Physics
51 terms
·
StudBud Administration
·
5 plays
Imported from external platform
Flashcards
51 cards
F
Practice quiz
P
Host live
L
Questions
51
Answers
1
A sonographer increases the line density from 1 line per degree of sector to 3 lines. What is the consequence
temporal resolution improves
frame rate increases
image quality decreases
temporal resolution degrades
2
Which of the following is associated with uniform brightness of an image?
threshold
gain
reject
compensation
3
increasing the number of scan lines in one frame improves which of the following?
axial resolution
temporal resolution
elevational resolution
lateral resolution
4
Electronic noise is reduced in the ultrasound system by this method:
demodulation
amplification
reject
rectification
5
Which of the following will require the TGCs to be adjusted in the most shallow portion of the display?
5 MHz linear phased array transducer
3 MHz mechanical scanner
4 MHz continuous wave transducer
2 MHz annular phased array transducer
6
The lines per frame and the frame rate determine the pulse repetition frequency?
False
True
7
The ratio of the largest to the smallest signal that a system can handle is termed:
Pulse Repetition Frequency
Threshold
Apodization
Dynamic Range
8
an adjustment is made that increased the patient exposure to ultrasound energy. Which control below was adjusted?
output power
TGC
dynamic range
receiver overall gain
9
With regard to ALARA, what is the best way to image deeper?
decrease the PRF
increase the overall gain
increase the TGCs
decrease the transducer's frequency
10
All of the following decrease temporal resolution except
narrow sector
deeper imaging
lower frame rate
multi-focus imaging
11
You have expanded the image sector width to improve visuals What can you do to maintain the same temporal resolution
increase the digitization bit depth
decrease the number of pixels in the image matrix
decrease the number of focal zones
increase the number of scan lines
12
You wish to improve contrast resolution to enhance the visibility of the lesion. you can do this by doing what?
increasing overall gain
increasing the acoustic power output
decreasing the scan line density
changing the gray scale map assignment
13
The fundamental limitation of temporal resolution is acoustic velocity.
False
True
14
the sonographer turns off the multi-focus feature. What is a consequence of this action
imaging depth increases
temporal resolution degrades
frame rate decreases
temporal resolution improves
15
Which of the following is associated with uniform amplification of all signals?
reject
gain
compensation
threshold
16
What is the rationale for the ALARA principle?
cavitation
climate change
carbon footprint
patient exposure
17
What control should you adjust to account for the attenuation of sound as it propagates through tissue?
depth gain compensation
acoustic output power
focusing
rejection
18
Referring to the image above, which adjustment is needed?
decrease the gain
decrease the frequency
increase the reject level
decrease the output power
19
in real time scanning, the required PRF depend on the number of --- per frame and ---
scans, scan
lines, frame
foci, propagation
echoes, pulsing
20
Each completion scan of the sound beam produces an image on the display that is called a __________.
picture
frame
cine loop
window
21
Refer to the image above. Which adjustment is best when the image does not display any difference in tissue density?
increase the transducer frequency
adjust the dynamic range
increase the receiver gain
increase the output power
22
what receiver function listed below is NOT adjustable?
amplification and rejection
rejection
demodulation
compensation
23
Which receiver function converts the negative portion of the signal to positive?
rectification
amplification
enveloping
demodulation
24
if the image's near field was difficult to see, what adjustment is needed?
decrease the TGC's in the far field
increase the overall gain
increase the TGC's in the near field
decrease the overall gain
25
which of the following resolutions improves when the frame rate increases?
spatial
lateral
longitudinal
temporal
26
what two systems affect frame rate?
number of pulses per frame, period
number of pulses per frame, frequency
imaging depth, number of pulses per frame
imaging depth, PRF
27
What system control should you adjust to account for sound attenuation with depth?
Dynamic range
Time gain compensation
Frame averaging
Focus position
28
The critical factor in determining frame rate, line density, and imaging depth is the type of transducer used.
True
False
29
As frame rate increases, the image quality may degrade.
False
True
30
The lines per frame and the frame rate determine the sound wave's frequency?
True
False
31
Which operator control affects frame rate?
transmit power
compression
scan depth
amplification
32
What part of the ultrasound instrument is responsible for apodization, beam steering, focusing, and aperture control?
memory
reciever
beam former
pulser
33
Which of the following adjustments would NOT decrease frame rate?
increasing the scan line density
increasing the receiver gain
increasing the scanning depth
increase the number of transmit focal zones
34
a sonographer changes the image sector size from 90 degrees to 45 degrees frame rate remains unchanged What else changed
the line density was doubled
the temporal resolution was doubled
the imaging depth was halved
the sector size was doubled
35
Preamplification processes extremely weak signals that are susceptible to noise and often takes place in the transducer.
True
False
36
if the image's far field is difficult to see, what adjustment is needed?
increase the overall gain
decrease the TGC's in the near field
decrease the overall gain
increase the TGC's in the far field
37
what system control determines the amount of amplification that occurs in the reciever?
gain
rectification
dynamic range
acoustic power output
38
Increasing the number of foci reduces
frame rate
contrast resolution
detail resolution
pulse repetition
39
An entire ultrasound image is too dark. What is the first adjustment that should be made to make the image brighter?
increase dynamic range
increase TGC
increase output power
increase gain
40
which of the following would decrease temporal resolution?
decrease sector width
increase PRF
increase scan line density
decreasing the number of focal zones
41
What receiver function decreases the difference between the smallest and largest received signal amplitudes?
compensation
demodulation
rejection
compression
42
what is the frame rate if the ultrasound system creates an image in 0.02 seconds (1/50th sec)?
20Hz
15Hz
50Hz
100Hz
43
What is the most common way to improve signal-to-noise ratio?
Increase TGC
increase output power
increase demodulation
increase receiver gain
44
which operator control adjusts the intensity of the transmitted pulse
depth of scanning
output power
dynamic range
receiver gain
45
Which adjustment is needed to improve this image
adjust the swept gain
adjust the rect
increase the transducer frequency
increase the output power
46
what adjustment will better display the reflectors located in the region closest to the trasnducer?
adjust the dynamic range
use a higher frequency transducer
adjust the system's TGC's
decrease the output power
47
Which operator control adjusts the dynamic range of the displayed echoes?
focusing
scanning depth
transmit power
compression
48
What is the time needed to make a single image if the frame rate of the ultrasound system is 20 Hz?
.05 s
.15 Hz
.02 Hz
1s
49
A sonographer doubles the depth of view from 10 cm to 20 cm. If frame rate is the same, which one also changes?
multi-focus imaging is turned on
increased line density
narrow sector
wider sector
50
you wish to increase the frame rate to evaluate the fetal heart. What should you do
increase scan line density
decrease the sector width
increase the number of focal zones
decrease the system pulse repetition frequency
51
Temporal resolution is only determined by ________.
PRF
length of the pulse
frame rate
beam width